BACKGROUND

It remains unclear whether the curative result of paroxysmal atrial fibrillation (PAF) is a result of pulmonary vein (PV) isolation, PV antrum modification (PVAM), or both. We hypothesized that sufficient antrum modification (PVAM) is as important as PV isolation (PVI) for atrial fibrillation (AF) control and that PVAM can be evaluated by quantified lesion deployment using a force-sensing catheter.

METHODS AND

RESULTS

Patients of symptomatic PAF were randomly assigned 2:1 into a PVAM group or a circumferential PV isolation (CPVI) group. In the PVAM group, circumferential quantitative ablation evaluated by automatical VisiTag module was performed. In the CPVI group, conventional circumferential ablation was performed to achieve the end point of all-PV isolation. In total, 180 patients with PAF were enrolled and randomly assigned to either the PVAM group (n = 120) or the CPVI group (n = 60). A total of 179 patients successfully underwent ablation. In the PVAM group, 68 patients achieved all PVI (PVAM-PVI), while 51 did not (PVAM-non-PVI). At 18 months, there was no significant difference in the maintenance of sinus rhythm between the PVAM and CPVI groups (84.9 vs 79.7%, P = .382). The PVAM-PVI subgroup demonstrated a higher arrhythmia-free survival compared with the PVAM-non-PVI subgroup (92.6 vs 74.5%, P = .006) and the CPVI group (92.6 vs 79.7%, P = .036).

CONCLUSIONS

The trial shows that sufficient force-sensing guided PVAM can result in satisfying outcomes in PAF patients. Notably, sufficient PVAM with all-PV isolated will further increase the success rate.

Для цитирования: Xu Qiang, Ju Weizhu, Xiao Fangyi, Yang Bing, Chen Hongwu, Yang Gang, Zhang Fengxiang, Gu Kai, Li Mingfang, Wang Daowu, Chen Minglong. Circumferential pulmonary vein antrum ablation for the treatment of paroxysmal atrial fibrillation: A randomized controlled trial.. Pacing and clinical electrophysiology : PACE. 2020. DOI: 10.1111/pace.13863.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.