m+Medelevator.RU
← Поиск публикаций
Journal of cardiovascular electrophysiology · 2019

Three-dimensional image integration guidance for cryoballoon pulmonary vein isolation procedures.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bourier Felix, Vlachos Konstantinos, Lam Anna, Martin Claire A, Takigawa Masateru, Kitamura Takeshi, Massoullié Grégoire, Cheniti Ghassen, Frontera Antonio, Duchateau Josselin, Pambrun Thomas, Klotz Nicolas, Derval Nicolas, Denis Arnaud, Hocini Mélèze, Haïssaguerre Michel, Cochet Hubert, Jaïs Pierre, Sacher Frédéric

Аннотация

BACKGROUND: We present a new, easily applicable approach for the guidance of cryoballoon (CB) pulmonary vein isolation (PVI) procedures that use the combination of a 3D-mapping system image integration module and computed tomographic (CT)-derived anatomy. The aim of this retrospective, nonrandomized study was to investigate: (a) an alternative use for an established radiofrequency image integration module for cryo procedures; (b) a guidance technology for cryo PVI based on integrated CT anatomy; and (c) its clinical impact.

METHODS AND RESULTS: CT left atrium-angiography was performed in 50 consecutive patients before a CB PVI procedure, and a 3D reconstruction of the cardiac anatomy was segmented. A total of 25 patients were treated using conventional fluoroscopy; 25 patients were treated using the 3D image integration technique. In the image integration group, the CARTO3 UNIVU (Biosense Webster) module was used for image integration of 3D anatomy and fluoroscopic imaging. Transseptal puncture and cryo PVI were guided by 3D-overlay imaging. Procedures were feasible without complications in all patients and cryo PVI procedures were successfully guided using the image integration technique. The intraprocedural time needed to perform image integration was 37 ± 10 seconds. Fluoroscopy time was 31.7 ± 11.7 minutes in the conventional group and 20.1 ± 7.9 minutes in the image integration group (P < .001), procedure time was 116.3 ± 29.0 minutes in the conventional group vs 101.2 ± 20.9 minutes in the 3D group (P = .04).

CONCLUSION: 3D-overlay guidance of CB PVI is feasible, safe, and applicable in real time with minimal effort. It may significantly reduce radiation exposure by introducing 3D information, known from electroanatomic mapping systems, into cryo PVI procedures.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты