MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/anec.12712

Медицинская библиотека · Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2019

Electrocardiogram characteristics of P wave associated with successful pulmonary vein isolation in patients with paroxysmal atrial fibrillation: Significance of changes in P-wave duration and notched P wave.

Yanagisawa Satoshi, Inden Yasuya, Okamoto Hiroya, Fujii Aya, Sakamoto Yusuke, Mamiya Keita, Tomomatsu Toshiro, Shibata Rei, Murohara Toyoaki

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The mechanisms involved in changes in P wave following catheter ablation for atrial fibrillation (AF) are uncertain. This study aimed to assess the relationship between changes in P-wave morphology and pulmonary vein (PV) reconnection following ablation by the assessment of 12-lead surface electrocardiogram and signal-averaged electrocardiogram.

METHODS

This retrospective study included 115 consecutive patients with paroxysmal AF that underwent repeat ablation for recurrence following initial ablation. We investigated changes in P-wave morphology between baseline and repeat procedure in patients with and without PV reconnection. The study also included as validation group without recurrence (n = 67) following initial ablation.

RESULTS

The maximum P-wave duration (PWD) was significantly decreased from baseline to just after the procedure in all groups. However, for the PV reconnection group (n = 100), the maximum PWD was significantly increased again at the repeat procedure. In contrast, the maximum PWD was significantly reduced between baseline and repeat procedure in the non-PV reconnection group (n = 15). The signal-averaged PWD was significantly decreased from baseline to repeat procedure in the non-PV reconnection group, but, conversely, was increased in the PV reconnection group. In the non-PV reconnection group, the disappearance of notched P wave was detected in 8 of 15 patients (53%), which was significantly higher than in other groups (p = .001). A new or delayed notched P wave was identified in the PV reconnection group only. These results were confirmed in the validation group.

CONCLUSIONS

The reverse dynamics of PWD after initial shortening directly following ablation were significantly associated with PV reconnection.

Для цитирования: Yanagisawa Satoshi, Inden Yasuya, Okamoto Hiroya, Fujii Aya, Sakamoto Yusuke, Mamiya Keita, Tomomatsu Toshiro, Shibata Rei, Murohara Toyoaki. Electrocardiogram characteristics of P wave associated with successful pulmonary vein isolation in patients with paroxysmal atrial fibrillation: Significance of changes in P-wave duration and notched P wave.. Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc. 2019. DOI: 10.1111/anec.12712.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.