m+Medelevator.RU
← Поиск публикаций
Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir · 2019

Effect of cryoballoon ablation parameters on recurrence in patients with paroxysmal atrial fibrillation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Demirtaş Abdullah Orhan, İçen Yahya Kemal, Dönmez Yurdaer, Koca Hasan, Kaypakli Onur, Şahin Durmuş Yıldıray, Koç Mevlüt

Аннотация

OBJECTIVE: The aim of this research was to investigate the relationship between atrial fibrillation (AF) recurrence and second generation cryoballoon ablation (CBA) procedural parameters in patients with non-valvular paroxysmal AF (PAF).

METHODS: A total of 131 patients with a PAF diagnosis who underwent second-generation CBA (59 male; mean age: 55.2±10.6 years) were enrolled. Recurrence was defined as the detection of AF on a 12-lead electrocardiography (ECG) recording, or an attack lasting at least 30 seconds observed on Holter ECG records. CBA procedural data and echocardiographic findings were recorded and compared.

RESULTS: After 1 year of follow-up, AF recurrence was detected in 27 patients. Patients with recurrence were older and had higher rates of hypertension and diabetes (p<0.05 for both). Left atrial diameter, left atrial volume (LaV), left atrial volume index, and the averaged warming angle (calculated by combining lowest temperature point and balloon temperature at 20°C point) were significantly higher in the recurrence group. Balloon warming time was significantly longer in the non-recurrence group (p<0.001). In binary logistic regression analysis, the averaged warming angle (odds ratio [OR]: 1.559, 95% confidence interval [CI]: 1.342-1.811; p<0.001) and LaV (OR: 1.063, 95% CI: 1.028-1.100; p<0.001) were found to be independent parameters for predicting recurrence. The cutoff value of the warming angle obtained with ROC curve analysis was 50° for the prediction of recurrence (sensitivity: 94.3%, specificity: 88.5%, area under the curve: 0.909; p<0.001). The cutoff value of LaV obtained by ROC curve analysis was 53.5 for prediction of recurrence (sensitivity: 77.8%, specificity: 74.5%; p<0.001).

CONCLUSION: Measurement of balloon warming angle during CBA and increased LaV may predict the AF recurrence.