MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ipej.2019.05.002

Медицинская библиотека · Indian pacing and electrophysiology journal · 2019

Impact of cryoballoon-guided pulmonary vein isolation on non-invasive autonomic tests in patients with paroxysmal atrial fibrillation.

Galloo Xavier, Abugattas Juan-Pablo, Tijskens Maxime, Dendale Paul, Varnavas Varnavas, Wolf Michael, De Cocker Jeroen, Schwagten Bruno, Sieira Juan, Ströker Erwin, Chierchia Gian-Battista, de Asmundis Carlo, De Greef Yves

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Pulmonary vein isolation (PVI) modulates the intrinsic cardiac autonomic nervous system (ANS). We evaluated the impact of PVI on 5 non-invasive autonomic tests.

METHODS

Thirty patients (76% male, mean age 60.37 ± 9.02 years) with paroxysmal atrial fibrillation (AF) underwent cryoballoon-guided PVI. Five autonomic tests were performed 24hrs before and after PVI (N = 30) and repeated after 6months (N = 22). Parasympathetic function was measured by heart rate (HR) variability during deep breathing (E/I ratio, I-E difference), Valsalva maneuver (Valsalva-ratio) and head-up tilt test (30/15 ratio). Sympathetic function was measured by systolic BP response to sustained handgrip and 10' tilting and by diastolic BP response to cold water.

RESULTS

24hrs after PVI, baseline HR increased from 57.93 ± 9.06 bpm to 71.10 ± 12.75 bpm (p < 0.001). At 6 months, baseline HR was lower than immediately post-PVI (62.59 ± 7.89 vs 71.36 ± 13.58 bpm, p = 0.032) but still higher in comparison to pre-PVI (62.59 ± 7.89 vs 57.09 ± 8.80 bpm, p < 0.001). No differences were seen in baseline BP and parasympathetic tests acutely and at 6months. Besides an acute lowering in systolic BP increase during handgrip test, all sympathetic tests remained unchanged.

CONCLUSIONS

An acute HR increase attenuated at 6months and an acute lowered systolic BP response to sustained handgrip were the only changes after cryoballoon-guided PVI. Non-invasive autonomic tests seem therefore not appropriate to evaluate the autonomic modulatory effect of PVI, either due to a too limited sensitivity or a too localized effect of PVI to influence test results.

Для цитирования: Galloo Xavier, Abugattas Juan-Pablo, Tijskens Maxime, Dendale Paul, Varnavas Varnavas, Wolf Michael, De Cocker Jeroen, Schwagten Bruno, Sieira Juan, Ströker Erwin, Chierchia Gian-Battista, de Asmundis Carlo, De Greef Yves. Impact of cryoballoon-guided pulmonary vein isolation on non-invasive autonomic tests in patients with paroxysmal atrial fibrillation.. Indian pacing and electrophysiology journal. 2019. DOI: 10.1016/j.ipej.2019.05.002.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.