The impact of ECG synchronization during acquisition of left‑atrium computed tomography model on radiation dose and arrhythmia recurrence rate after catheter ablation of atrial fibrillation - a prospective, randomized study.

Skala T, Tudos Z, Homola M, Moravec O, Kocher M, Cerna M, Ctvrtlik F, Odstrcil F, Langova K, Klementova O, Taborsky M

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The impact of ECG gating during computed tomography (CT) acquisition of left atrium (LA) model on radiation dose, image quality and ablation event-free survival rate after catheter ablation (CA) of atrial fibrillation (AF) is not well defined.

METHODS

Sixty-two patients with paroxysmal atrial fibrillation were randomized for two types of LA CT (with vs without ECG gating) before CA. Pulmonary veins isolation was performed in all patients. Patients were followed for 12 months after CA.

RESULTS

There was no difference between the groups in CA length (131.61±32.57 vs 119.84±33.18 min; p=0.108), CA fluoroscopy time (4.48±2.19 vs 3.89±1.83 min; p=0.251), CA fluoroscopy dose (3.99±2.79 vs 3.91 vs2.91 Gy*cm2; p=0.735), visual data quality (1.77±0.88 vs 2.0±0.63; p=0.102) and registration error (2.42±0.72 vs 2.43±0.46 mm; p=0.612). We found a significant difference in CT Dose index (89.55±5.99 vs 19.19±4.33 mGy; p<0.0001) and Dose Length product (1438.87±147.75 vs 328.21±73.83 mGy*cm; p<0.0001). Twelve months after CA, 25 of 31 patients in the gated group and 24 of 31 patients in the non-gated group were free of AF (80.65 vs 77.42 %; p=0.838).

CONCLUSION

ECG gating of computed tomography of LA before AF ablation burdens patients with a four times higher radiation dose while improving neither the quality of CT model or fusion of CT with the electroanatomic map. As a result, it has no significant impact on arrhythmia recurrence rate after ablation (Tab. 3, Fig. 3, Ref. 25).

Для цитирования: Skala T, Tudos Z, Homola M, Moravec O, Kocher M, Cerna M, Ctvrtlik F, Odstrcil F, Langova K, Klementova O, Taborsky M. The impact of ECG synchronization during acquisition of left‑atrium computed tomography model on radiation dose and arrhythmia recurrence rate after catheter ablation of atrial fibrillation - a prospective, randomized study.. Bratislavske lekarske listy. 2019. DOI: 10.4149/bll_2019_033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.