MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00002341-200007000-00005

Медицинская библиотека · Ophthalmic plastic and reconstructive surgery · 2000

Hydroxyapatite implant wrapping materials: analysis of fibrovascular ingrowth in an animal model.

Klapper S R, Jordan D R, Punja K, Brownstein S, Gilberg S M, Mawn L A, Grahovac S Z

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the influence of seven currently available spherical orbital implant wraps on host fibrovascularization of a hydroxyapatite (HA) orbital implant.

METHODS

Five groups of 3 (15 total) adult male New Zealand albino rabbits underwent enucleation with placement of a 12-mm HA implant wrapped in high-porosity expanded polytetrafluoroethylene (e-PTFE), processed bovine pericardium, or processed human pericardium, sclera, or fascia lata. Magnetic resonance imaging before and after the intravenous administration of gadolinium-diethylenetriamine pentaacetic acid (DTPA, 0.1 mol/kg) was performed immediately before exenteration. Five rabbits (one with each of the different implant wraps) were killed at 4, 8, and 12 weeks, and the operated socket was exenterated. Histopathologic sections of the implants were then compared with the results of our previous study using polyglactin 910 mesh and autologous sclera as HA orbital implant wraps.

RESULTS

Complete fibrovascularization of all the implants occurred by 12 weeks; however, HA implants wrapped with sclera, polyglactin mesh, and e-PTFE appeared to undergo more rapid fibrovascularization than spheres wrapped with other materials.

CONCLUSIONS

Although all of the implant wraps studied may be suitable substitutes for donor sclera, we prefer polyglactin mesh because it is readily available, inexpensive, and without risk of transmissible diseases.

Для цитирования: Klapper S R, Jordan D R, Punja K, Brownstein S, Gilberg S M, Mawn L A, Grahovac S Z. Hydroxyapatite implant wrapping materials: analysis of fibrovascular ingrowth in an animal model.. Ophthalmic plastic and reconstructive surgery. 2000. DOI: 10.1097/00002341-200007000-00005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.