MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0000000000001476

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2020

Assessing Corneal Speckle in Optical Coherence Tomography: A New Look at Glaucomatous Eyes.

Iskander D Robert, Kostyszak Małgorzata A, Jesus Danilo A, Majewska Małgorzata, Danielewska Monika E, Krzyżanowska-Berkowska Patrycja

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

SIGNIFICANCE: Optical coherence tomography speckle is used here in an unconventional way as the indirect source of information on tissue microstructure. The study reveals that the corneal speckle of glaucoma suspects has a similar relationship between the parameters of scattering exhibited in glaucoma patients.

PURPOSE: The purpose of this study was to evaluate the potential of optical coherence tomography imaging of the cornea in early diagnosis of glaucoma.

METHODS

Corneas of 64 subjects of three groups, including 18 primary open-angle glaucoma patients, 24 glaucoma suspects with normal levels of IOP and uncompromised visual field, and 22 age-matched controls, were imaged with spectral optical coherence tomography. A central region of interest in each optical coherence tomography image visualizing the stroma was automatically extracted, and the intensity data within that region were fit with the generalized gamma distribution. Its parameters describe the scatterer cross section and scatterer density and indirectly assess corneal microstructure. In addition, subjects underwent measurements of IOP, visual field, Heidelberg Retinal Tomography, retinal nerve fiber layer thickness, and biometry. Group means of all parameters were tested for equality. Within each group of subjects, correlation was evaluated between the statistical parameters of the corneal speckle.

RESULTS

Glaucoma suspects had statistically significantly different IOP, visual field parameters, mean retinal fiber layer thickness, and central corneal thickness from those of glaucoma patients but not from those of the control group. The parameters of the corneal speckle were not significantly different between the groups, but they showed a markedly higher and statistically significant coefficient of determination for glaucoma patients and suspects than that for the control group (0.927 and 0.707 vs. 0.336).

CONCLUSIONS

The results indicate that glaucoma suspects have similar relationship between the corneal scatterer cross section and scatterer density to that exhibited in the glaucoma patients but markedly different from that of healthy controls.

Для цитирования: Iskander D Robert, Kostyszak Małgorzata A, Jesus Danilo A, Majewska Małgorzata, Danielewska Monika E, Krzyżanowska-Berkowska Patrycja. Assessing Corneal Speckle in Optical Coherence Tomography: A New Look at Glaucomatous Eyes.. Optometry and vision science : official publication of the American Academy of Optometry. 2020. DOI: 10.1097/opx.0000000000001476.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.