MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/opo.12643

Медицинская библиотека · Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2019

Investigating the structure-function relationship using Goldmann V standard automated perimetry where glaucomatous damage is advanced.

Yanagisawa Mieko, Murata Hiroshi, Matsuura Masato, Fujino Yuri, Hirasawa Kazunori, Asaoka Ryo

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate if the structure-function relationship between circumpapillary retinal nerve fibre layer (cpRNFL) thickness and visual field (VF) thresholds is stronger when using the Goldmann V target rather than the Goldman III target where glaucomatous damage is advanced.

METHODS

Optical coherence tomography (OCT) and VF (Humphrey Field Analyzer 24-2 or 30-2) measurements with Goldmann III (SITA standard) and V (full-threshold) targets were carried out in 51 eyes of 51 patients with primary open angle glaucoma. The relationship between cpRNFL thicknesses in supero- and infero-temporal sectors, and VF sensitivity with the Goldmann III or V target was investigated.

RESULT: Visual field sensitivities (dB) both with the Goldmann III target and Goldmann V target showed a floor effect in the structure-function relationship against cpRNFL thickness, at approximately 60 μm. There was no significant relationship between visual field sensitivity measured with the Goldmann V target (dB scale: p = 0.12, 1/Lambert scale: p = 0.40; linear mixed models) and cpRNFL thickness, when corresponding visual field sensitivity, measured with the Goldmann III target, was <20 dB.

CONCLUSION

There was no improvement in the structure-function relationship using the Goldmann V target (full-threshold), compared to using the Goldmann III target (SITA standard), where glaucomatous damage was advanced.

Для цитирования: Yanagisawa Mieko, Murata Hiroshi, Matsuura Masato, Fujino Yuri, Hirasawa Kazunori, Asaoka Ryo. Investigating the structure-function relationship using Goldmann V standard automated perimetry where glaucomatous damage is advanced.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2019. DOI: 10.1111/opo.12643.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.