DOI 10.1038/s41433-019-0600-2

Медицинская библиотека · Eye (London, England) · 2019

Determinants of maximum cup depth in non-glaucoma and primary open-angle glaucoma subjects: a population-based study.

Zhang Qing, Zhang Ye, Xin Chen, Mao Yingyan, Cao Kai, Jan Catherine, Guo Chunyu, Wang Ningli, Thomas Ravi

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND/

OBJECTIVES

To study the associations of intraocular pressure (IOP) and retinal vessel diameters: central retinal arteriolar equivalent (CRAE) and central retinal venular equivalent (CRVE) with the maximum cup depth (MCD) in subjects with and without POAG.

SUBJECTS/

METHODS

Eligible subjects from the Handan Eye Study. All participants underwent physical and comprehensive eye examinations. Univariable and multivariable linear regression models assessed the association between MCD and other parameters.

RESULTS

Four thousand one hundred and ninety-four eligible nonglaucoma and 40 POAG subjects were analyzed. On univariable analysis, deeper MCD was significantly associated with younger age, male gender, lower systolic blood pressure (BP), higher IOP, higher estimated cerebro-spinal fluid pressure (ECSFP), lower estimated trans-laminal cribrosa pressure difference (ETLCPD), longer axial length, narrower CRAE, narrower CRVE, larger disc area (DA) and a lower prevalence of hypertension and diabetes. On multivariable analysis, significant independent determinants of MCD were larger DA (P < 0.001; beta: 0.042; B: 0.20; 95% CI: 0.19, 0.22), younger age (P < 0.001; beta: -0.09; B: -0.002; 95% CI: -0.003, -0.001), higher IOP (P < 0.01; beta: 0.040; B: 0.003; 95% CI: 0.001, 0.005), and narrower CRAE (P < 0.001; beta: -0.06; B: -0.001; 95% CI: -0.001, -0.0003). On adding ECSFP and ETLCPD to the model, MCD was associated with IOP but not with estimated CSFP and TLCPD. A 1 μm decrease in CRAE or 1 mmHg increase of IOP was associated with a 1 μm increase of MCD (P < 0.001) and 3 μm increase of MCD respectively (P = 0.009).

CONCLUSIONS

Narrow CRVE and higher IOP are associated with an increase in MCD.

Для цитирования: Zhang Qing, Zhang Ye, Xin Chen, Mao Yingyan, Cao Kai, Jan Catherine, Guo Chunyu, Wang Ningli, Thomas Ravi. Determinants of maximum cup depth in non-glaucoma and primary open-angle glaucoma subjects: a population-based study.. Eye (London, England). 2019. DOI: 10.1038/s41433-019-0600-2.