Therapeutic application of 20-kHz transcranial ultrasound in an embolic middle cerebral artery occlusion model in rats: safety concerns.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wilhelm-Schwenkmezger Thomas, Pittermann Patrick, Zajonz Katharina, Kempski Oliver, Dieterich Marianne, Nedelmann Max

Аннотация

BACKGROUND AND PURPOSE: Therapeutic application of diagnostic ultrasound has been shown to improve recanalization rates in patients with acute cerebral vessel occlusion. There is experimental evidence that low-frequency ultrasound may be superior. This study was designed to evaluate the therapeutic efficacy and safety of low-frequency ultrasound in an embolic middle cerebral artery occlusion model in rats. A parameter setting was used that had not previously shown any side effects and interactions with healthy rat brain tissue.

METHODS: Male Wistar rats were submitted to middle cerebral artery clot embolism and transcranial treatment with 20-kHz continuous-wave ultrasound (0.2 W/cm(2)), either alone or in combination with recombinant tissue-type plasminogen activator. Control groups received no treatment or recombinant tissue-type plasminogen activator alone. Outcome assessment consisted of determination of infarct volume and neurological evaluation.

RESULTS: Eleven animals treated with ultrasound died during the follow-up period of 7 days, compared with 2 animals in the control groups (P=0.028). In 3 animals, subarachnoid hemorrhage was detected (1 in the control group). The other animals that died displayed secondary worsening after an initial period of normal vigilance. Histological examination revealed massive edema formation. In surviving animals, no benefit of treatment could be demonstrated.

CONCLUSIONS: In this study, 20-kHz continuous-wave ultrasound caused death in a significant number of animals. Ultrasound at 20 kHz does not seem to be suitable for transcranial therapeutic cerebral application. The data underline the necessity to obtain further animal data to establish the safety limits of frequency and power output.