European journal of nuclear medicine and molecular imaging · 2007
Variations in 123I-metaiodobenzylguanidine (MIBG) late heart mediastinal ratios in chronic heart failure: a need for standardisation and validation.
СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Verberne Hein J, Habraken Jan B A, van Eck-Smit Berthe L F, Agostini Denis, Jacobson Arnold F
Аннотация
BACKGROUND: There is lack of validation and standardisation of acquisition parameters for myocardial (123)I-metaiodobenzylguanidine (MIBG). This lack of standardisation hampers large scale implementation of (123)I-MIBG parameters in the evaluation of patients with chronic heart failure (CHF).
METHODS: In a retrospective multi-centre study (123)I-MIBG planar scintigrams obtained on 290 CHF patients (82% male; 58% dilated cardiomyopathy; New York Heart Association [NYHA classification] > I) were reanalysed to determine the late heart-to-mediastinum ratio (H/M).
RESULTS: There was a large variation in acquisition parameters. Multivariate forward stepwise regression showed that a significant proportion (31%, p < 0.001) of the variation in late H/M could be explained by a model containing patient-related variables and acquisition parameters. Left ventricular ejection fraction (p < 0.001), type of collimation (p < 0.001), acquisition duration (p = 0.001), NYHA class (p = 0.028) and age (p = 0.034) were independent predictors of late H/M.
CONCLUSIONS: Acquisitions parameters are independent contributors to the variation of semi-quantitative measurements of cardiac (123)I-MIBG uptake. Improved standardisation of cardiac (123)I-MIBG imaging parameters would contribute to increased clinical applicability for this procedure.
METHODS: In a retrospective multi-centre study (123)I-MIBG planar scintigrams obtained on 290 CHF patients (82% male; 58% dilated cardiomyopathy; New York Heart Association [NYHA classification] > I) were reanalysed to determine the late heart-to-mediastinum ratio (H/M).
RESULTS: There was a large variation in acquisition parameters. Multivariate forward stepwise regression showed that a significant proportion (31%, p < 0.001) of the variation in late H/M could be explained by a model containing patient-related variables and acquisition parameters. Left ventricular ejection fraction (p < 0.001), type of collimation (p < 0.001), acquisition duration (p = 0.001), NYHA class (p = 0.028) and age (p = 0.034) were independent predictors of late H/M.
CONCLUSIONS: Acquisitions parameters are independent contributors to the variation of semi-quantitative measurements of cardiac (123)I-MIBG uptake. Improved standardisation of cardiac (123)I-MIBG imaging parameters would contribute to increased clinical applicability for this procedure.
Предметные рубрики MeSH
3-IodobenzylguanidineAdultAgedAged, 80 and overChronic DiseaseCoronary Artery DiseaseEuropeHeartHeart FailureHumansMediastinumMiddle AgedPrognosisRadionuclide ImagingRadiopharmaceuticalsReference StandardsReproducibility of ResultsRetrospective StudiesRisk AssessmentRisk FactorsSensitivity and SpecificityVentricular Dysfunction, Left