MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acssensors.5c04006

Медицинская библиотека · ACS sensors · 2025

Machine Learning-Augmented Graphene Transistor Biosensing: Quantitative Platform Validation and Immunotesting of Hepatitis E.

Albesa Sofia, Giménez Ezequiel, Piccinini Jose M, Vizoso-Pinto María G, Marmisollé Waldemar A, Piccinini Esteban, Azzaroni Omar

СтатьяПеревод пока не подготовлен

Аннотация

Graphene-based chips face persistent sensor-to-sensor variability due to manufacturing defects and polymer contamination, limiting their analytical reliability for healthcare applications. Here, we demonstrate that the integration of a machine learning (ML) model with graphene field-effect transistors (GFETs) enables quantitative and calibration-free analytical sensing. Using Random Forest Regression and field-effect-related figures of merit, the model enabled robust, quantitative predictions across analytes of varying chemical nature─from small ions to viral antigens. pH sensing was used as a reference system to validate the augmented platform. Compared with the reference analytical model, ML enabled a marked improvement of accuracy, from 93 to 97%, and a reduction of the coefficient of variability, from 14 to 3%. Then, the ML-integrated GFETs were applied to chloride detection, the gold standard for cystic fibrosis diagnosis. Finally, using GFETs functionalized with llama nanobodies, we targeted the ORF2 antigen of the Hepatitis E virus. ML integration significantly enhanced immunoassay sensitivity-specificity from 89-69% to 100-100% and allowed the quantitative prediction of antigen concentration. Furthermore, the ML-augmented test demonstrated a strong performance for HEV antigen detection in capillary blood samples without the need for any sample pretreatment.

Для цитирования: Albesa Sofia, Giménez Ezequiel, Piccinini Jose M, Vizoso-Pinto María G, Marmisollé Waldemar A, Piccinini Esteban, Azzaroni Omar. Machine Learning-Augmented Graphene Transistor Biosensing: Quantitative Platform Validation and Immunotesting of Hepatitis E.. ACS sensors. 2025. DOI: 10.1021/acssensors.5c04006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.