m+Medelevator.RU
← Поиск публикаций
Journal of cataract and refractive surgery · 2025

Development of machine learning-based models for vault prediction in implantable collamer lens surgery according to implant orientation.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

González-Cruces Timoteo, Aguilar-Salazar Francisco Javier, Marfany Tort Jordi, Sánchez-Ventosa Álvaro, Villarrubia Alberto, Mateu Jose Lamarca, Barraquer Rafael I, Pardina Sergio, Cerdán Palacios David, Cano-Ortiz Antonio

Аннотация

PURPOSE: To develop a prediction model based on machine learning to calculate the postoperative vault and the ideal implantable collamer lens (ICL) size, considering for the first time the implantation orientation in a White population.

SETTING: Arruzafa Ophthalmological Hospital (Cordoba, Spain) and Barraquer Ophthalmology Center (Barcelona, Spain).

DESIGN: Multicenter, randomized, retrospective study.

METHODS: Anterior segment biometric data from 235 eyes of patients who underwent ICL lens implantation surgery were collected using the anterior segment optical coherence tomography CASIA II to train and validate 5 types of multiple regression models based on advanced machine learning techniques. To perform an external validation, a dataset of 45 observations was used.

RESULTS: The Pearson correlation coefficient between observed and predicted values was similar in the 5 models in the external validation, with least absolute shrinkage and selection operator regression being the highest ( r = 0.62, P < .001), followed by random forest regression model ( r = 0.60, P < .001) and backward stepwise regression ( r = 0.58, ρ < 0.001). In addition, the predictions generated by the different models showed closer agreement with the actual vault compared with the Nakamura formulas. Using the new methods, about 70% of the observations had a prediction error below 150 μm.

CONCLUSIONS: Advanced forms of regressions models based on machine learning allow satisfactory calculation of the ideal lens size, offering greater precision to surgeons customizing surgery according to implant orientation.