Development of machine learning-based models for vault prediction in implantable collamer lens surgery according to implant orientation.

González-Cruces Timoteo, Aguilar-Salazar Francisco Javier, Marfany Tort Jordi, Sánchez-Ventosa Álvaro, Villarrubia Alberto, Mateu Jose Lamarca, Barraquer Rafael I, Pardina Sergio, Cerdán Palacios David, Cano-Ortiz Antonio

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To develop a prediction model based on machine learning to calculate the postoperative vault and the ideal implantable collamer lens (ICL) size, considering for the first time the implantation orientation in a White population.

SETTING

Arruzafa Ophthalmological Hospital (Cordoba, Spain) and Barraquer Ophthalmology Center (Barcelona, Spain).

DESIGN

Multicenter, randomized, retrospective study.

METHODS

Anterior segment biometric data from 235 eyes of patients who underwent ICL lens implantation surgery were collected using the anterior segment optical coherence tomography CASIA II to train and validate 5 types of multiple regression models based on advanced machine learning techniques. To perform an external validation, a dataset of 45 observations was used.

RESULTS

The Pearson correlation coefficient between observed and predicted values was similar in the 5 models in the external validation, with least absolute shrinkage and selection operator regression being the highest ( r = 0.62, P < .001), followed by random forest regression model ( r = 0.60, P < .001) and backward stepwise regression ( r = 0.58, ρ < 0.001). In addition, the predictions generated by the different models showed closer agreement with the actual vault compared with the Nakamura formulas. Using the new methods, about 70% of the observations had a prediction error below 150 μm.

CONCLUSIONS

Advanced forms of regressions models based on machine learning allow satisfactory calculation of the ideal lens size, offering greater precision to surgeons customizing surgery according to implant orientation.

Для цитирования: González-Cruces Timoteo, Aguilar-Salazar Francisco Javier, Marfany Tort Jordi, Sánchez-Ventosa Álvaro, Villarrubia Alberto, Mateu Jose Lamarca, Barraquer Rafael I, Pardina Sergio, Cerdán Palacios David, Cano-Ortiz Antonio. Development of machine learning-based models for vault prediction in implantable collamer lens surgery according to implant orientation.. Journal of cataract and refractive surgery. 2025. DOI: 10.1097/j.jcrs.0000000000001623.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.