MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2024.12.017

Медицинская библиотека · American journal of ophthalmology · 2024

Analyzing the Effect of Surgical and Corneal Parameters on the Postoperative Refractive Outcomes of Smile in Myopic Eyes Based on Machine Learning.

Zhang Mingdong, Ji Shufan, Huo Yan, Bai Shaohu, Tao Ziheng, Zhang Jiamei, Cao Huazheng, Zou Haohan, Zhao Xinheng, Wang Yan

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To analyze the influence of individual parameters on the postoperative refractive outcomes of small incision lenticule extraction (SMILE) in myopic eyes using machine learning.

DESIGN

Retrospective Clinical Cohort Study

METHODS

This study included 477 patients (922 eyes) of SMILE and divided them into two groups based on postoperative spherical equivalent (SE) ≤ -0.50D to analyze the factors influencing postoperative refractive outcomes. The XGBoost model took 72 clinical parameters (34 biomechanical, 31 morphological, 4 surgical-related, and 3 preoperative refractive parameters) as features; randomly selected 42 eyes from the good refractive outcomes group and all eyes (a total of 42 eyes) from the poor refractive outcomes group to conduct 100 times influence factors analysis.

RESULTS

The 10 most important factors influencing postoperative refractive outcomes included 3 surgery-related parameters (PTA, LTmax, and RST), 3 corneal biomechanical parameters (HC Time, Deflection Amp Max (ms), and SSI), 2 corneal morphological parameters (R Per F and Rs F), and 2 preoperative refractive parameters (SE and SD). When PTA ≥ 25.09%, LTmax ≥ 139μm, SE ≤ -7.00D, or SD ≤ -6.75D, the postoperative SE significantly increased (all P < 0.05), with averages of -0.183D, -0.171D, -0.188D, and -0.184D. After controlling for age, intraocular pressure, and corneal thickness, the postoperative SE significantly increased when HC time ≥ 17.422 and Deflection Amp Max (ms) ≥ 16.616, reaching -0.209D and -0.202D.

CONCLUSIONS

More corneal tissue ablation, longer HC Time and Deflection Amp Max (ms), lower SSI, and higher preoperative refractive error may result in poor postoperative refractive outcomes.

Для цитирования: Zhang Mingdong, Ji Shufan, Huo Yan, Bai Shaohu, Tao Ziheng, Zhang Jiamei, Cao Huazheng, Zou Haohan, Zhao Xinheng, Wang Yan. Analyzing the Effect of Surgical and Corneal Parameters on the Postoperative Refractive Outcomes of Smile in Myopic Eyes Based on Machine Learning.. American journal of ophthalmology. 2024. DOI: 10.1016/j.ajo.2024.12.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.