Coronary CT angiography in step-and-shoot technique with 256-slice CT: impact of the field of view on image quality, craniocaudal coverage, and radiation exposure.

Muenzel Daniela, Noel Peter B, Dorn Franziska, Dobritz Martin, Rummeny Ernst J, Huber Armin

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the effect of a small field of view (FOV) for step-and-shoot coronary computed tomography angiography (CCTA) on craniocaudal z-coverage per scan step, image quality, and radiation exposure.

METHODS

53 patients underwent prospectively ECG-gated CCTA on a 256-slice MDCT scanner using either a FOV > 250 mm (group 1, n = 29) or a FOV ≤ 250 mm (group 2, n = 24). Craniocaudal z-coverage was determined on coronal multiplanar reformations. Image noise, signal-to-noise ratio, contrast-to-noise ratio, and qualitative image parameters were assessed. Radiation dose was estimated from the dose length product and was standardized for a scan range from the main pulmonary artery to the diaphragm in order to make both groups comparable.

RESULTS

Diagnostic image quality was achieved in 91.3% of the coronary artery segments of group 1 and 89.9% in group 2 (p = 0.201). There were no major differences in image noise, SNR, and CNR between both groups. A smaller FOV leads to an increase of craniocaudal coverage of a single CT scan step (r = -0.879; p ≤ 0.001). There was an increase of 23.8% of the mean z-coverage per scanned subvolume in group 2 (59.9 mm vs. 48.8mm). Radiation dose was significantly lower in group 2 (229 vs. 285 mGy cm, respectively).

CONCLUSION

The use of a small transverse FOV for step-and-shoot CCTA at a wide detector CT scanner leads to an increased z-coverage. 2 scan volumes are enough to image the cardiac anatomy. Radiation dose is decreased without negative impact on image quality.

Для цитирования: Muenzel Daniela, Noel Peter B, Dorn Franziska, Dobritz Martin, Rummeny Ernst J, Huber Armin. Coronary CT angiography in step-and-shoot technique with 256-slice CT: impact of the field of view on image quality, craniocaudal coverage, and radiation exposure.. European journal of radiology. 2011. DOI: 10.1016/j.ejrad.2011.04.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.