MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/ma19183860

Медицинская библиотека · Materials (Basel, Switzerland) · 2026

Porous Ti-6Al-4V Architectures in Load-Bearing Orthopedic Reconstruction: A Critical Narrative Review of the Translational Gap Across Microstructure, Fatigue, Surface Function, and Clinical Failure Modes.

Kutluay Gündüz Ercan, Erdoğan Fatih, Dinçel Yaşar Mahsut

СтатьяОбзорПеревод пока не подготовлен

Аннотация

An aging population and a rising revision burden are increasing demand for bone-compatible load-bearing implants. Because the elastic modulus of conventional Ti-6Al-4V (~110 GPa) exceeds that of cortical bone (7-30 GPa), stress shielding can drive bone resorption and aseptic loosening. Two solution lines have emerged: low-modulus β-type alloys and porous architectures. Focusing on additive manufacturing (AM), this critical narrative review synthesizes the evidence along the axis of clinical failure modes. Materials science has lowered β-Ti's modulus to ~40 GPa in bulk, yet clinical implants rely predominantly on porous conventional Ti-6Al-4V: the low effective modulus (single-digit GPa) comes from architecture, not alloying. These architectures range from porous fixation surfaces on solid acetabular shells to predominantly porous constructs-revision knee cones and sleeves, acetabular augments, and spinal interbody cages. In the acetabular cohorts, where clinical evidence is concentrated, short- to mid-term survivorship is favorable though heterogeneous; revisions were driven mainly by infection and instability, with aseptic loosening low. Two tools are proposed: a synthesis matrix setting laboratory claims alongside clinical evidence for each design parameter, and a 16-item minimum reporting checklist. Applied to the 12 primary series reviewed, the checklist found manufacturing and architecture-verification parameters largely unreported even where clinical outcomes are well documented.

Для цитирования: Kutluay Gündüz Ercan, Erdoğan Fatih, Dinçel Yaşar Mahsut. Porous Ti-6Al-4V Architectures in Load-Bearing Orthopedic Reconstruction: A Critical Narrative Review of the Translational Gap Across Microstructure, Fatigue, Surface Function, and Clinical Failure Modes.. Materials (Basel, Switzerland). 2026. DOI: 10.3390/ma19183860.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.