MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/1471-0528.15830

Медицинская библиотека · BJOG : an international journal of obstetrics and gynaecology · 2019

Effectiveness of spontaneous ovulation as monitored by urinary luteinising hormone versus induced ovulation by administration of human chorionic gonadotrophin in couples undergoing gonadotrophin-stimulated intrauterine insemination: a randomised controlled trial.

Thomas S, Sebastian T, Karthikeyan M, Mangalaraj A M, Aleyamma T K, Kamath M S

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare effectiveness of spontaneous ovulation monitored by urinary luteinising hormone (LH) versus induced ovulation by administration of human chorionic gonadotrophin (hCG) in couples undergoing gonadotrophin-stimulated intrauterine insemination (IUI).

DESIGN

Randomised controlled trial.

SETTING

University-level infertility unit.

POPULATION: Couples with unexplained infertility, mild endometriosis, mild male factor infertility and polycystic ovarian syndrome.

METHODS

Couples were randomised to an LH group (Group A), in which urinary LH was measured daily to detect spontaneous ovulation, or an hCG group (Group B), in which urinary hCG was administered as a trigger.

MAIN OUTCOME MEASURES: Clinical pregnancy rate. Secondary outcomes - ongoing pregnancy, live birth, multiple pregnancy and miscarriage rates.

RESULTS

A total of 392 couples were randomised with 196 in each arm. The clinical pregnancy rate per woman randomised was 14/196 (7.1%) in the LH arm versus 15/196 (7.6%) in the hCG arm (P = 0.847, which was not statistically significant). Similarly, the ongoing pregnancy rates [13/196 (6.6%) versus 14/196 (7.1%); P = 0.84] and the live birth rates [13/196 (6.6%) versus 14/196 (7.1%); P = 0.84] between the two groups did not show any significant difference. The duration of stimulation and gonadotrophin dosage also did not differ significantly between the two methods.

CONCLUSION

There was no significant difference in clinical pregnancy rates when urinary LH and hCG trigger were compared as methods to time insemination in women undergoing gonadotropin-stimulated IUI.

TWEETABLE ABSTRACT: A randomised controlled study showing similar effectiveness between two different methods of timing IUI.

Для цитирования: Thomas S, Sebastian T, Karthikeyan M, Mangalaraj A M, Aleyamma T K, Kamath M S. Effectiveness of spontaneous ovulation as monitored by urinary luteinising hormone versus induced ovulation by administration of human chorionic gonadotrophin in couples undergoing gonadotrophin-stimulated intrauterine insemination: a randomised controlled trial.. BJOG : an international journal of obstetrics and gynaecology. 2019. DOI: 10.1111/1471-0528.15830.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.