MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_1492_20

Медицинская библиотека · Indian journal of ophthalmology · 2020

Safety and efficacy of toric implantable collamer lens V4c model - A retrospective South Indian study.

Chaitanya S Ravi, Anitha Venugopal, Ravindran Meenakshi, Ghorpade Aditya, Rengappa Ramakrishnan, Uduman Mahammed Sithiq

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: : The aim of this study was to evaluate the safety, efficacy, and complications of V4c Toric implantable collamer Lens (TICL) implantation for myopic astigmatism in the south Indian population.

METHODS

In this retrospective observational case series, a total of 109 eyes of 67 patients who underwent V4c TICL implantation (ICL, V4C Staar Surgical, Nidau, Switzerland) between January 2012 and August 2019 were studied with a minimum follow-up period of 6 months (mean 24 months). The main outcome measures were objective and subjective refraction, uncorrected distance visual acuity, corrected distance visual acuity (CDVA), safety, predictability, adverse events, and postoperative complications.

RESULTS

At 6 months, mean manifest refractive spherical equivalent (SE) decreased from -10.90 ± 3.7D preoperatively to -0.02 ± 0.13D postoperatively (P < 0.001) and mean cylinder decreased from -2.3 ± 1.3 D preoperatively to -0.04 ± 0.2 D postoperatively (P < 0.001). Postoperatively, SE within ± 0.5 D and ± 1.0 D of attempted correction were achieved in 96.3 (105 eyes) and 100% (109 eyes), respectively. Manifest refractive cylinder within ± 0.5 D and ± 1.0 D of attempted correction were achieved in 97.2 (106 eyes) and 100% (109 eyes), respectively. Sixty-two percent (68 eyes) showed no change in CDVA postoperatively, and no eye had lost lines of CDVA. The safety index was 1.12, and the efficacy index was 1.10. Complications were seen in two eyes (1.8%) due to high postoperative vault requiring secondary surgical interventions.

CONCLUSION

V4c TICL is a highly effective, safe, and predictable option in treating myopic astigmatism with excellent improvement in vision and spectacle independence.

Для цитирования: Chaitanya S Ravi, Anitha Venugopal, Ravindran Meenakshi, Ghorpade Aditya, Rengappa Ramakrishnan, Uduman Mahammed Sithiq. Safety and efficacy of toric implantable collamer lens V4c model - A retrospective South Indian study.. Indian journal of ophthalmology. 2020. DOI: 10.4103/ijo.ijo_1492_20.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.