DOI 10.1097/j.jcrs.0000000000000259
Comparison of the rotational stability between plate-haptic toric and C-loop haptic toric IOLs in myopic eyes.
Аннотация
PURPOSE: To compare the rotational stability of a plate-haptic toric intraocular lens (IOL) vs a C-loop haptic toric IOL in myopic cataract eyes.
SETTING
Eye and Ear, Nose, and Throat Hospital of Fudan University, China.
DESIGN
Prospective, randomized, controlled study.
METHODS
Cataract eyes with axial length (AL) more than 24.5 mm were randomly assigned to receive implantation of a C-loop haptic toric IOL (AcrySof Toric IOL) (Group A) or a plate-haptic toric IOL (AT TORBI 709M IOL) (Group B). IOL rotation, residual astigmatism, visual acuity, and higher-order aberrations (HOAs) evaluated with OPD-Scan III aberrometer were compared at 3 months postoperatively.
RESULTS
In total, 62 eyes of 62 patients were eligible for analysis: 31 in Group A and 31 in Group B. The mean rotation of toric IOLs was greater in Group A than that in Group B (8.00 ± 3.60 degrees vs 4.42 ± 3.24 degrees, respectively, P < .001), especially when IOLs were vertically placed. IOL rotation was positively correlated with AL in Group A, whereas no such correlations were found in Group B. Residual astigmatism in Group A was greater than that in Group B (-0.76 ± 0.30 diopter [D] vs -0.51 ± 0.29 D, respectively, P = .001). Fewer eyes achieved residual astigmatism of 0.50 D or less in Group A than in Group B (38.71% vs 64.52%). Group A had worse postoperative uncorrected visual acuity and higher total HOAs and coma for a 6.0 mm pupil than Group B, whereas postoperative corrected visual acuity was not different between the 2 groups.
CONCLUSIONS
The plate-haptic toric IOL might be a better choice for myopic cataract eyes with corneal astigmatism because of reduced postoperative rotation.