DOI 10.1097/j.jcrs.0000000000000290

Медицинская библиотека · Journal of cataract and refractive surgery · 2020

Visual performance after bilateral toric extended depth-of-focus IOL exchange targeted for micromonovision.

Georgiev Stefan, Palkovits Stefan, Hirnschall Nino, Döller Birgit, Draschl Petra, Findl Oliver

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate overall patient satisfaction, spectacle independence, binocular visual acuity, rotational stability, prevalence of optical phenomena, and decentration and tilt after bilateral toric extended depth-of-focus intraocular lens (EDOF IOL) implantation targeted for micromonovision.

SETTING

Department of Ophthalmology, Hanusch Hospital, Vienna, Austria.

DESIGN

Prospective case series.

METHODS

The study included 52 eyes of 26 patients with regular corneal astigmatism from 0.75 to 2.60 diopters (D) that were implanted bilaterally with a toric EDOF IOL targeted for micromonovision. Postoperative visual acuity, astigmatism reduction, rotation, tilt, decentration, spectacle independence, patient satisfaction, and photic phenomena were assessed.

RESULTS

For the 52 eyes studied, binocular means expressed in logarithm of the minimum angle resolution for postoperative corrected distance, uncorrected distance, uncorrected intermediate, and uncorrected near visual acuities were -0.10 (±0.12), -0.01 (±0.13), 0.01 (±0.14), and 0.13 (±0.14), respectively. Mean refractive astigmatism reduction was 1.31 ± 0.67 D resulting in a mean refractive cylinder of 0.47 ± 0.46 D at the 3-month visit. Mean postoperative rotation was 3.5 ± 3.5 degrees, at the 3-month time point. Most prevalent dysphotopsia were halos, starburst, and glare affecting 6 (23%), 6 (23%), and 5 (19%) of 26 patients, respectively; 20 (77%) of 26 patients reported spectacle independence, with 19 (95%), 19 (95%), and 14 (70%) of 20 patients questioned being satisfied with distance, intermediate, and near vision, respectively.

CONCLUSIONS

Toric EDOF IOL implantation targeted for micromonovision resulted in reliable reduction of preoperative astigmatism with a high degree of postoperative rotational predictability and centration, enabling functional distance, intermediate, and near vision, which manifested itself in high patient satisfaction.

Для цитирования: Georgiev Stefan, Palkovits Stefan, Hirnschall Nino, Döller Birgit, Draschl Petra, Findl Oliver. Visual performance after bilateral toric extended depth-of-focus IOL exchange targeted for micromonovision.. Journal of cataract and refractive surgery. 2020. DOI: 10.1097/j.jcrs.0000000000000290.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.