BACKGROUND

In Scotland there has been an outbreak of mumps with over 4000 confirmed cases in the last 2 years. As laboratory diagnosis is usually requested on patients with symptoms, a prompt diagnosis early in the illness is required.

OBJECTIVES

To assess the performance of the five different commercial IgM-ELISAs used in Scottish Virus laboratories.

STUDY

DESIGN

The Specialist Virology Laboratory (SVC) Edinburgh distributed a serum panel to all Scottish laboratories that diagnose mumps by IgM-ELISA. The panel consisted of 45 sera from patients with confirmed mumps (date of onset known for 44/45) and 11 sera from patients with alternative diagnoses. Each laboratory performed their own commercial IgM-ELISAs blindly and reported results to the SVC Edinburgh.

RESULTS

Sensitivity ranged from 24% to 51%. Assays performed better on samples taken later than 10 days after onset of symptoms. Specificity was about 82% for most assays.

CONCLUSION

The sensitivity of commercial mumps IgM-ELISAs varied greatly. The Microimmune mumps-IgM ELISA had the best overall sensitivity in acute serum specimens. Diagnostic laboratories should be developing the means to perform direct detection of mumps virus for acute presentation and requesting convalescent bloods, if acute blood samples have no detectable IgM.

Для цитирования: Krause Claudia H, Molyneaux Pamela J, Ho-Yen Darrel O, McIntyre Paul, Carman William F, Templeton Kate E. Comparison of mumps-IgM ELISAs in acute infection.. Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology. 2006. DOI: 10.1016/j.jcv.2006.10.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.