Koch Douglas D, Wang Li, Abulafia Adi, Holladay Jack T, Hill Warren
Аннотация
PURPOSE: To evaluate the accuracy and usefulness of certain methods of analyzing astigmatic vectors.
SETTING: Cullen Eye Institute, Baylor College of Medicine, Houston, Texas.
DESIGN: Case samples.
METHODS: Using 2 sample cases for analysis of corneal surgically induced astigmatism and an actual toric intraocular lens (IOL) case, univariate analyses from the ASSORT program were compared to double-angle plots of preoperative and postoperative astigmatism and prediction errors.
RESULTS: Certain univariate figures for analyzing the 2 sample cases were misleading. For the toric IOL case, some of the key outcome vectors were inaccurate.
CONCLUSIONS: ASSORT's univariate analysis of astigmatic vectors can be unpredictably erroneous and misleading. Recommended vector analyses should include double-angle plots with centroids and confidence ellipses of preoperative and postoperative astigmatism and the prediction errors, along with means and standard deviations of these vector magnitudes.
SETTING: Cullen Eye Institute, Baylor College of Medicine, Houston, Texas.
DESIGN: Case samples.
METHODS: Using 2 sample cases for analysis of corneal surgically induced astigmatism and an actual toric intraocular lens (IOL) case, univariate analyses from the ASSORT program were compared to double-angle plots of preoperative and postoperative astigmatism and prediction errors.
RESULTS: Certain univariate figures for analyzing the 2 sample cases were misleading. For the toric IOL case, some of the key outcome vectors were inaccurate.
CONCLUSIONS: ASSORT's univariate analysis of astigmatic vectors can be unpredictably erroneous and misleading. Recommended vector analyses should include double-angle plots with centroids and confidence ellipses of preoperative and postoperative astigmatism and the prediction errors, along with means and standard deviations of these vector magnitudes.