MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20200714-01

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2020

Long-term Vector Outcomes of SMILE in Correcting Moderate to High With-the-Rule Astigmatism Under Astigmatism Axis Marked Condition.

Yang Xiaonan, Liu Quan, Lin Haiqin, Xie Yi, Feng Qiting

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the vector outcomes of small incision lenticule extraction (SMILE) in correcting moderate to high myopic astigmatism under astigmatic axis marked condition.

METHODS

In a prospective, longitudinal, interventional study, 71 eyes (71 patients) that had with-the-rule preoperative cylinder refraction exceeding 1.50 diopters (D) were corrected with the VisuMax femtosecond laser (Carl Zeiss Meditec AG) at Zhongshan Ophthalmic Center. Refractive outcomes and astigmatic vector were evaluated preoperatively and at 1, 3, 6, and 30 months postoperatively.

RESULTS

At 30 months postoperatively, the efficacy and safety indexes were 1.04 ± 0.18 and 1.15 ± 0.17, respectively. The magnitude of the surgically induced astigmatism (SIA) (2.13 ± 0.71 D at 1 month [P1m-pre = .018], 2.12 ± 0.72 D at 3 months [P3m-pre = .006], 2.13 ± 0.69 D at 6 months [P6m-pre = .010], and 2.19 ± 0.72 D at 30 months [P30m-pre < .001]) was slightly higher than that of the target induced astigmatism (TIA) (2.07 ± 0.69 D). Only the y-coordinate of the SIA vector had a significant overcorrection compared to that of the TIA vector (P1m-pre = .033, P3m-pre = .011, P6m-pre = .012, P30m-pre < .001). The corrected index (CI = |SIA|/|TIA|) varied from 1.03 ± 0.07 at 1 month to 1.06 ± 0.10 at 30 months, which was higher when correcting moderate astigmatism than when correcting high astigmatism (P = .041) at 30 months postoperatively.

CONCLUSIONS

SMILE had long-term safety, efficacy, predictability, and stability when correcting moderate to high myopic astigmatism under astigmatism axis marked condition. Meanwhile, a cylinder overcorrection was observed due to the overcorrection of y-coordinate astigmatic power, which implied that the vector adjustment of the cylinder refraction nomogram should be considered. [J Refract Surg. 2020;36(9):585-591.].

Для цитирования: Yang Xiaonan, Liu Quan, Lin Haiqin, Xie Yi, Feng Qiting. Long-term Vector Outcomes of SMILE in Correcting Moderate to High With-the-Rule Astigmatism Under Astigmatism Axis Marked Condition.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2020. DOI: 10.3928/1081597x-20200714-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.