MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/pmic.200600432

Медицинская библиотека · Proteomics · 2006

High-throughput analysis of mumps virus and the virus-specific monoclonal antibody on the arrays of a cationic polyelectrolyte with a spectral SPR biosensor.

Kim Hyun-Soo, Jung Se-Hui, Kim Sang-Hyun, Suh In-Bum, Kim Woo Jin, Jung Jae-Wan, Yuk Jong Seol, Kim Young-Myeong, Ha Kwon-Soo

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

We investigated the potential use of a spectral surface plasmon resonance (SPR) biosensor in a high-throughput analysis of mumps virus and a mumps virus-specific mAb on the arrays of a cationic polyelectrolyte, poly(diallyldimethylammonium chloride) (PDDA). The PDDA surface was constructed by electrostatic adsorption of the polyelectrolyte onto a monolayer of 11-mercaptoundecanoic acid (MUA). Poly-L-lysine was also adsorbed onto the MUA monolayer and compared with the PDDA surface in the capacity of mumps virus immobilization. The PDDA surface showed a higher adsorption of mumps virus than the poly-L-lysine surface. The SPR signal caused by the virus binding onto the PDDA surface was proportional to the concentration of mumps virus from 0.5 x 10(5) to 14 x 10(5) pfu/mL. The surface structure of the virus arrays was visualized by atomic force microscopy. Then, a dose-dependent increase in the SPR signal was observed when various concentrations of the antimumps virus antibody in buffer or human serum were applied to the virus arrays, and their interaction was specific. Thus, it is likely that the spectral SPR biosensor based on the cationic polyelectrolyte surface may provide an efficient system for a high-throughput analysis of intact virus and serodiagnosis of infectious diseases.

Для цитирования: Kim Hyun-Soo, Jung Se-Hui, Kim Sang-Hyun, Suh In-Bum, Kim Woo Jin, Jung Jae-Wan, Yuk Jong Seol, Kim Young-Myeong, Ha Kwon-Soo. High-throughput analysis of mumps virus and the virus-specific monoclonal antibody on the arrays of a cationic polyelectrolyte with a spectral SPR biosensor.. Proteomics. 2006. DOI: 10.1002/pmic.200600432.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.