m+Medelevator.RU
← Поиск публикаций
American journal of ophthalmology · 2020

Influence of Artificial Tears on Keratometric Measurements in Cataract Patients.

Сравнительное исследованиеСтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Röggla Veronika, Leydolt Christina, Schartmüller Daniel, Schwarzenbacher Luca, Meyer Elias, Abela-Formanek Claudette, Menapace Rupert

Аннотация

PURPOSE: To assess the influence of artificial tears of different viscosity on K-readings prior to cataract surgery.

DESIGN: Prospective randomized crossover, before-and-after clinical study.

METHODS: Setting: Department of Ophthalmology, Medical University of Vienna.

PATIENT POPULATION: A total of 123 eyes of 80 patients prior to cataract surgery were assigned to 2 groups based on normal and dry eyes.

INTERVENTION: Two native baseline keratometries were followed by instillation of either high- or low-viscosity eye drops. Keratometry was repeated 30 seconds, 2 minutes, and 5 minutes after instillation.

MAIN OUTCOME MEASURES: Influence of eye drops of different viscosity in normal and dry eyes on short time K-readings.

RESULTS: Repeatability between native baseline measurements was high (standard deviation = 0.02 mm in normal and in dry eyes). In normal and dry eyes, a statistically significant increase in measurement variability after instillation of both low-viscosity and high-viscosity eye drops was observed (P < .01). Measurement variability was most pronounced between baseline measurement and 30 seconds and diminished over time. Variability of K-readings appeared higher in dry eyes compared with normal eyes. Astigmatism changed more than 0.5 diopters in 13.2% of normal eyes and 34.4% in dry eyes using eye drops of high viscosity.

CONCLUSION: Tear film-stabilizing eye drops prior to keratometry measurements influenced K-readings significantly, especially in dry eyes. A time period of more than 5 minutes should be allowed to pass after instillation of eye drops. The higher the viscosity of the eye drops, the stronger the influence and the longer its persistence.