MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11325-025-03441-w

Медицинская библиотека · Sleep & breathing = Schlaf & Atmung · 2025

Proposition of a new, minimally-invasive, software smartphone device to predict sleep apnea and its severity.

Frija Justine, Millet Juliette, Béquignon Emilie, Covali Ala, Cathelain Guillaume, Houenou Josselin, Benzaquen Hélène, Geoffroy Pierre A, Bacry Emmanuel, Grajoszex Mathieu, d'Ortho Marie-Pia

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: obstructive sleep apnea is underdiagnosed due to limited access to polysomnography (PSG). We aimed to assess the performances of Apneal®, an application recording sound and movements thanks to a smartphone's microphone, accelerometer and gyroscope, to estimate patients' apnea-hypopnea index (AHI).

METHODS

monocentric proof-of-concept study with a first manual scoring step, then automatic detection of respiratory events from recorded signals using a sequential deep-learning model (version 0.1 of Apneal® automatic scoring of respiratory events, end 2022), in adult patients.

RESULTS

46 patients (women 34%, BMI 28.7 kg/m²) were included. Sensitivity of manual scoring was 0.91 (95% CI [0.8-1]) for IAH > 15 and 0.85 [0.67-1] for AHI > 30, and positive predictive values (PPV) 0.89 [0.76-0.97] and 0.94 [0.8-1]. We obtained an AUC-ROC of 0.85 (95% CI [0.69-0.96]) and AUC-PR of 0.94 (95% CI [0.84-0.99]) for the identification of AHI > 15, and AUC-ROC of 0.95 [0.860.99] and AUC-PR of 0.93 [0.81-0.99] for AHI > 30. The ICC between the AHI estimated manually, and from the PSG is 0.89 (p = 6.7 × 10- 17), Pearson correlation 0.90 (p = 1.25 × 10- 17). Automatic scoring found sensitivity of 1 [0.95-1], PPV of 0.9 [0.8-0.9] for AHI > 15, and sensitivity 0.95 [0.84-1], PPV 0.69 [0.52-0.85] for AHI > 30. The ICC between the estimated AHI, and PSG scorings is 0.84 (p = 5.4 × 10- 11) and Pearson correlation is 0.87 (p = 1.7 × 10- 12).

CONCLUSION

Manual scoring of smartphone-based signals is possible and accurate compared to PSG-based scorings. Automatic scoring method based on a deep learning model provides promising results.

TRIAL REGISTRATION: NCT03803098.

Для цитирования: Frija Justine, Millet Juliette, Béquignon Emilie, Covali Ala, Cathelain Guillaume, Houenou Josselin, Benzaquen Hélène, Geoffroy Pierre A, Bacry Emmanuel, Grajoszex Mathieu, d'Ortho Marie-Pia. Proposition of a new, minimally-invasive, software smartphone device to predict sleep apnea and its severity.. Sleep & breathing = Schlaf & Atmung. 2025. DOI: 10.1007/s11325-025-03441-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.