Is optical coherence tomography an effective device for evaluation of tear film meniscus in patients with acne rosacea?

Eroglu F C, Karalezli A, Dursun R

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the tear meniscus using Fourier-domain optical coherence tomography (FD-OCT) in patients with acne rosacea and to determine the relationship between tear film break-up tests (TBUT), Schirmer test and FD-OCT values and to compare them with that of healthy controls.

METHODS

One hundred and four patients with acne rosacea and 104 body mass index age-sex-matched healthy subjects were enrolled in this prospective case-control study. Tear meniscus height (TMH), tear meniscus depth (TMD), and tear meniscus cross-sectional area (TMA) were measured using FD-OCT (RTVue-100); TBUT, Schirmer test and dry eye questionnaire (OSDI) were evaluated. Correlation was assessed using Spearman's correlation coefficient.

RESULTS

Mean TMH, TMD, TMA, TBUT, and Schirmer test values of acne rosacea patients were significantly lower than and OSDI score significantly higher than those of controls. Tear mensicus values were significantly correlated with OSDI scores, TBUT, and Schirmer test results. The intraobserver intraclass correlation coefficient (ICC) for tear parameters ranged from 0.90 to 0.96 and interobserver ICC ranged from 0.92 to 0.94, which revealed high reproducibility for all measurements parameters both acne rosacea and control subjects. Accuracy of dry eye diagnosis by FD-OCT was 60.4% for TMH, 58.7% for TMD, and 64.8% for TMA.

CONCLUSION

Tear meniscus measurement with FD-OCT could provide acceptable specificity and sensitivity in diagnosis of dry eye in acne rosacea patients.

Для цитирования: Eroglu F C, Karalezli A, Dursun R. Is optical coherence tomography an effective device for evaluation of tear film meniscus in patients with acne rosacea?. Eye (London, England). 2016. DOI: 10.1038/eye.2015.277.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.