MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4321/s1130-01082005000500004

Медицинская библиотека · Revista espanola de enfermedades digestivas · 2005

Is routine endoanal ultrasound useful in anal fistulas?

Pascual Migueláñez I, García-Olmo D, Martínez-Puente M C, Pascual Montero J A

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the effectiveness of endoanal ultrasound with hydrogen peroxide enhancement in the assessment of anal fistula (tract and internal opening), and to value the utility of this examination for anal or perianal suppuration when performed by a colorectal surgeon trained in this technique.

PATIENTS: Endoanal ultrasound was performed in 103 patients with anal or perianal suppuration. Twenty patients were excluded: 9 had the external opening closed, and 11 had cryptoglandular abscesses. All ultrasound scans were performed by the same explorer using a BK Diagnostic Ultrasound System with a 7 MHz endoprobe. The examination was based on the identification of the three anal planes, then hydrogen peroxide was infused and the procedure was repeated.

RESULTS

Out of 83 patients included, 11 had a perianal sinus and 72 an anal fistula. In all fistulas the main tract was found: 24 were inter-sphinteric (33.33%), 33 trans-sphincteric (45.83%), 3 supra-sphincteric (4.17%), and 12 extra-sphincteric (16.67%). An internal opening was identified in 69 (95.83%).

CONCLUSIONS

Endoanal ultrasound with hydrogen peroxide enhancement is an effective examination to visualize fistulous tracts and internal openings. We think it is highly useful for anal or perianal suppuration to identify abscesses, to recognize a perianal sinus, to check the sphincteric condition, and to plan subsequent surgery.

Для цитирования: Pascual Migueláñez I, García-Olmo D, Martínez-Puente M C, Pascual Montero J A. Is routine endoanal ultrasound useful in anal fistulas?. Revista espanola de enfermedades digestivas. 2005. DOI: 10.4321/s1130-01082005000500004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.