MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ruq.0000000000000738

Медицинская библиотека · Ultrasound quarterly · 2026

Is There a Safer Way for Thyroid Nodule Ablation: Comparative Study of Cooled and Uncooled Systems in Benign Thyroid Nodule Treatment.

Mahmutoğlu Abdullah Soydan, Yildirim Gülşah, Aksoy Direnç Özlem, Özgür Eren, Mahmutoğlu Özdeş, Meltem Emine, Karagöz Yeşim

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Ultrasound-guided microwave ablation (MWA) has emerged as a safe and effective nonsurgical treatment option for benign thyroid nodules (BTN), with ongoing debate regarding the comparative performance of cooled (cMWA) and uncooled (uMWA) MWA systems.

PURPOSE: This study aims to address this debate by comparing the safety and efficacy of cMWA and uMWA and to confirm the effectiveness of both systems in the treatment of BTN.

MATERIAL AND

METHODS

Data from 73 patients who underwent MWA treatment for BTN between September 2019 and May 2022 were retrospectively evaluated. A total of 24 patients [mean age: 43.87 ± 9.5 years; 15 females (62.5%)] with solid or predominantly solid nodules, who received a single session of cMWA (n = 12) or uMWA (n = 12), were included. Nodule volume reduction, cosmetic scores, clinical symptoms, side effects, and complications were recorded.

RESULTS

Nodule volumes significantly decreased at the third and sixth month follow-ups, with similar volume reduction ratios between cMWA and uMWA (60.30 ± 8 vs 57.29 ± 8.2 at 3 mo and 78.03 ± 6 vs 77.55 ± 10 at 6 mo). Energy power and ablation duration differed significantly between groups (uMWA: 15 watts, 26.92 ± 4.9 min vs cMWA: 30 watts, 14.77 ± 4.79 min). One major and 2 minor complications (nodule rupture and superficial hematoma) occurred only in the cMWA group. Cosmetic concerns and pressure symptoms improved in both groups during follow-up.

CONCLUSION

uMWA provided similar volume reduction to cooled systems and demonstrated a favorable safety profile. However, observed differences in complications require cautious interpretation because of the limited sample size and the inherent difference in power settings.

Для цитирования: Mahmutoğlu Abdullah Soydan, Yildirim Gülşah, Aksoy Direnç Özlem, Özgür Eren, Mahmutoğlu Özdeş, Meltem Emine, Karagöz Yeşim. Is There a Safer Way for Thyroid Nodule Ablation: Comparative Study of Cooled and Uncooled Systems in Benign Thyroid Nodule Treatment.. Ultrasound quarterly. 2026. DOI: 10.1097/ruq.0000000000000738.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.