MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ejcts/ezy361

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2019

The effects of low suction on digital drainage devices after lobectomy using video-assisted thoracoscopic surgery: a randomized controlled trial†.

Holbek Bo Laksáfoss, Christensen Merete, Hansen Henrik Jessen, Kehlet Henrik, Petersen René Horsleben

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

The optimal level of suction on digital chest drainage devices after lobectomy using video-assisted thoracoscopic surgery (VATS) is unknown and varies between thoracic centres. In this randomized controlled trial, we assessed the potential benefits of low suction of -2 cmH2O compared to -10 cmH2O, using a digital drainage device.

METHODS

Two hundred and twenty-eight patients were randomized into 2 groups after VATS lobectomy for suspected or confirmed lung cancer. Primary outcome was time to chest drain removal. Drain data were obtained from the digital drainage devices, and patient data were obtained from medical records during admission, with a follow-up until postoperative day 30.

RESULTS

For the -2 cmH2O and -10 cmH2O groups, median (interquartile range) drainage duration was 27.4 h (23.3-71.2) and 47.5 h (24.5-117.8) (P = 0.047), and the incidence of prolonged air leak >5 days was 14.4% and 24.3% (P = 0.089), respectively. Median total fluid production was 566 h (329-1155) ml and 795 h (454-1605) ml (P = 0.007). Median time to consistent air leak cessation (<20 ml/min) was 5.2 h (0.3-34.2) and 23.7 h (0.8-90.8) (P < 0.001). There were no differences in the proportion or the size of the pneumothorax or subcutaneous emphysema after drain removal, and no differences were observed in postoperative morbidity. Median length of in-hospital stay was 2.0 days (2.0-5.8) and 3.0 days (2.0-9.0) (P = 0.18).

CONCLUSIONS

A low suction level significantly shortened drainage duration, time to air leak cessation and total fluid production, without increasing morbidity.

CLINICAL TRIAL REGISTRATION NUMBER: NCT02911259.

Для цитирования: Holbek Bo Laksáfoss, Christensen Merete, Hansen Henrik Jessen, Kehlet Henrik, Petersen René Horsleben. The effects of low suction on digital drainage devices after lobectomy using video-assisted thoracoscopic surgery: a randomized controlled trial†.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2019. DOI: 10.1093/ejcts/ezy361.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.