m+Medelevator.RU
← Поиск публикаций
Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2011

Evaluation of a novel point-of-care cryptococcal antigen test on serum, plasma, and urine from patients with HIV-associated cryptococcal meningitis.

Оценочное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jarvis Joseph N, Percival Ann, Bauman Sean, Pelfrey Joy, Meintjes Graeme, Williams G Ntombomzi, Longley Nicky, Harrison Thomas S, Kozel Thomas R

Аннотация

BACKGROUND: Many deaths from cryptococcal meningitis (CM) may be preventable through early diagnosis and treatment. An inexpensive point-of-care (POC) assay for use with urine or a drop of blood would facilitate early diagnosis of cryptococcal infection in resource-limited settings. We compared cryptococcal antigen (CRAG) concentrations in plasma, serum, and urine from patients with CM, using an antigen-capture assay for glucuronoxylomannan (GXM) and a novel POC dipstick test.

METHODS: GXM concentrations were determined in paired serum, plasma, and urine from 62 patients with active or recent CM, using a quantitative sandwich enzyme-linked immunosorbent assay (ELISA). A dipstick lateral-flow assay developed using the same monoclonal antibodies for the sandwich ELISA was tested in parallel. Correlation coefficients were calculated using Spearman rank test.

RESULTS: All patients had detectable GXM in serum, plasma, and urine using the quantitative ELISA. Comparison of paired serum and plasma showed identical results. There were strong correlations between GXM levels in serum/urine (r(s) = 0.86; P < .001) and plasma/urine (r(s) = 0.85; P < .001). Levels of GXM were 22-fold lower in urine than in serum/plasma. The dipstick test was positive in serum, plasma, and urine in 61 of 62 patients. Dipstick titers correlated strongly with ELISA. Correlations between the methods were 0.93 (P < .001) for serum, 0.94 (P < .001) for plasma, and 0.94 (P < .001) for urine.

CONCLUSIONS: This novel dipstick test has the potential to markedly improve early diagnosis of CM in many settings, enabling testing of urine in patients presenting to health care facilities in which lumbar puncture, or even blood sampling, is not feasible.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты