MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2008.04.018

Медицинская библиотека · Journal of cataract and refractive surgery · 2008

Effect of a new cohesive ophthalmic viscosurgical device on corneal protection and intraocular pressure in small-incision cataract surgery.

Neumayer Thomas, Prinz Ana, Findl Oliver

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the corneal protective and intraocular pressure (IOP) effects of a new cohesive ophthalmic viscosurgical (OVD), Neocrom Cohesive (sodium hyaluronate 1.4%), with those of Healon (sodium hyaluronate 1.0%) in cataract surgery.

SETTING

Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.

METHODS

This randomized patient-masked examiner-masked study with fellow-eye comparison comprised 29 cataract surgery patients. Surgery was performed with Neocrom Cohesive in 1 eye and Healon in the other eye. Central corneal thickness (CCT) was measured preoperatively and 1 day and 3 months postoperatively; endothelial cell density (ECD), preoperatively and 3 months postoperatively; and IOP, preoperatively and 6 hours and 1 day postoperatively.

RESULTS

The mean CCT change from preoperatively to postoperatively in the Neocrom Cohesive, respectively, group and Healon group was +16.0 microm +/- 25.7 (SD) (P<.01) and +7.0 +/- 17.1 microm (P<.05), respectively, at 1 day and -5.7 +/- 10.8 microm (P<.01) and -4.7 microm +/- 9.5 microm) (P<.01), respectively, at 3 months. The mean ECD change at 3 months was 8 +/- 155 cells/mm(2) in the Neocrom Cohesive group (P = .8) and -46 +/- 139 cells/mm(2) in the Healon group (P = .08). The mean IOP increase was +2.2 +/- 3.5 mm Hg (P<.01) and +1.4 +/- 4.2 mm Hg (P = .14), respectively, 6 hours postoperatively and +0.9 +/- 4.3 mm Hg (P = .37) and 0.0 +/- 3.5 mm Hg (P = .77), respectively, at 1 day.

CONCLUSION

There was no significant difference between Neocrom Cohesive and Healon in the changes in CCT, ECD, and IOP after cataract surgery.

Для цитирования: Neumayer Thomas, Prinz Ana, Findl Oliver. Effect of a new cohesive ophthalmic viscosurgical device on corneal protection and intraocular pressure in small-incision cataract surgery.. Journal of cataract and refractive surgery. 2008. DOI: 10.1016/j.jcrs.2008.04.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.