MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3349/ymj.2007.48.4.627

Медицинская библиотека · Yonsei medical journal · 2007

Comparison of higher-order aberration and contrast sensitivity in monofocal and multifocal intraocular lenses.

Kim Chang Yeom, Chung So-Hyang, Kim Tae-Im, Cho Young Jae, Yoon Geunyoung, Seo Kyoung Yul

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The visual performance of pseudophakic eyes depends on the type of intraocular lenses (IOLs) that are implanted. Aspherical and multifocal IOLs have recently been developed to improve visual quality after cataract surgery, but multifocal IOLs can be associated with decreased contrast sensitivity (CS), halos, and glare. This study compares the visual performance of monofocal and multifocal IOLs by measurement of higher-order aberrations (HOAs) and CS values.

MATERIALS AND

METHODS

HOAs and CS values of 42 eyes with implanted monofocal IOLs and 40 eyes with implanted multifocal IOLs were measured preoperatively and more than 6 months after surgery. In the multifocal IOL group, HOAs and CS values were also measured with addition of a trial lens of -0.5 diopter (D) to evaluate the compensatory effect on spherical aberration.

RESULTS

CS values of the multifocal IOL group were significantly lower than those of the monofocal IOL group for all spatial frequencies tested (p<0.01), and the spherical aberration was significantly higher in the multifocal IOL group than in the monofocal IOL group (p<0.001). Addition of a -0.5 D lens to the multifocal IOL group decreased the difference in CS between the two groups (p=0.003).

CONCLUSION

Increased spherical aberration may contribute to lower CS in the multifocal IOL group. In such cases, CS can be improved by addition of a -0.5 D lens to compensate for the spherical aberration.

Для цитирования: Kim Chang Yeom, Chung So-Hyang, Kim Tae-Im, Cho Young Jae, Yoon Geunyoung, Seo Kyoung Yul. Comparison of higher-order aberration and contrast sensitivity in monofocal and multifocal intraocular lenses.. Yonsei medical journal. 2007. DOI: 10.3349/ymj.2007.48.4.627.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.