MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.06-1358

Медицинская библиотека · Investigative ophthalmology & visual science · 2007

Multiplex bead analysis of vitreous humor of patients with vitreoretinal disorders.

Banerjee Somnath, Savant Vijay, Scott Robert A H, Curnow S John, Wallace Graham R, Murray Philip I

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Vitreoretinal disorders are frequently characterized by increased vitreous levels of cellular mediators, including cytokines, chemokines, and growth factors. The study was conducted to investigate whether multiplex bead analysis could identify disease-specific profiles of these mediators in a variety of vitreoretinal diseases.

METHODS

Levels of 19 mediators were measured: the cytokines IL-6, IL-10, IL-12, IL-13, IL-15, IL-17, TNF, IFN-gamma, granulocyte-macrophage-colony-stimulating factor (GM-CSF), and granulocyte-stimulating factor (G-CSF); the chemokines CCL2, CCL3, CCL4, CCL5, CCL11, and CXCL8; and the growth factors epidermal growth factor (EGF), FGF, and VEGF, by using multiplex bead analysis of vitreous humor of 58 eyes undergoing vitrectomy for a variety of vitreoretinal disorders.

RESULTS

The predominant mediators detected were IL-6, CXCL8, and CCL2. The most complex pattern of mediators was seen in patients with proliferative vitreoretinopathy (PVR) and included a mixture of cytokines, chemokines, and growth factors. Patients with chronic uveitis showed a limited mediator pattern that did not suggest either a Th1 or Th2 response. By comparison, patients with lens-induced uveitis (LIU) showed significantly greater levels of cytokines than did patients with chronic uveitis, including IFN-gamma and IL-12, with a trend toward an acute Th1 inflammatory response. Moreover, in samples from patients with LIU, CXCL8 inversely correlated with time after initial surgery and duration of treatment.

CONCLUSIONS

Multiplex bead analysis allows the measurement of multiple mediators from a single vitreous sample. The data confirm patterns of mediators previously described in different vitreoretinal conditions. In addition, LIU mediator levels correlate with duration of treatment and time after cataract surgery.

Для цитирования: Banerjee Somnath, Savant Vijay, Scott Robert A H, Curnow S John, Wallace Graham R, Murray Philip I. Multiplex bead analysis of vitreous humor of patients with vitreoretinal disorders.. Investigative ophthalmology & visual science. 2007. DOI: 10.1167/iovs.06-1358.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.