m+Medelevator.RU
← Поиск публикаций
Journal of cataract and refractive surgery · 2007

Quality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation: effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision.

СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Denoyer Alexandre, Le Lez Marie-Laure, Majzoub Samuel, Pisella Pierre-Jean

Аннотация

PURPOSE: To compare ocular performance and quality of vision in pseudophakic eyes with an aspherical intraocular lens (IOL) or a conventional spherical IOL.

SETTING: Bretonneau University Hospital, Tours, France.

METHODS: Twenty patients (40 eyes) were randomly divided in 2 equal groups to bilaterally receive the aspherical Tecnis Z9000 IOL (AMO) or the spherical CeeOn Edge 911 IOL (AMO). Contrast sensitivity was measured and ocular wavefront analysis performed before surgery and 6 months after. Patients completed the Activities of Daily Vision Scale (ADVS) to evaluate patient-centered visual outcomes. Other examinations included refraction before and after mydriasis and pupil diameter.

RESULTS: The mean postoperative best corrected visual acuity (logMAR) was 0.03 +/- 0.05 (SD) in the Tecnis group and 0.01 +/- 0.05 in the CeeOn Edge group (P = .41). Refractive evaluation with mydriasis showed a mean myopic shift as low as -0.02 +/- 0.36 diopter (D) in the Tecnis group and -0.51 +/- 0.37 D in the CeeOn Edge group (P = .001). Mesopic contrast sensitivity at high spatial frequencies was significantly better in the Tecnis group (P<.001), while contrast sensitivity under photopic and glare conditions was not different between the 2 groups. Spherical aberration was significantly lower in the Tecnis group, which had a mean Z(4)(0) of 0.01 +/- 0.06 microm, than in the CeeOn Edge group, which had a mean Z(4)(0) of 0.16 +/- 0.12 microm (P<.001). The global score on the ADVS was not statistically different between groups; however, quality of distance vision was better in the Tecnis group than in the CeeOn Edge group (mean 99.0 +/- 2.0 versus 89.2 +/- 3.4) (P<.001).

CONCLUSION: Implantation of an aspherical IOL with a negative spherical aberration resulted in reduced ocular spherical aberration and improved mesopic contrast sensitivity and led to better subjective quality of vision.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты