Journal of cataract and refractive surgery · 2006
Posterior capsule opacification after implantation of a hydrophilic or a hydrophobic acrylic intraocular lens: one-year follow-up.
Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kugelberg Maria, Wejde Gisela, Jayaram Hari, Zetterström Charlotta
Аннотация
PURPOSE: To evaluate the effect of hydrophilic and hydrophobic single-piece acrylic intraocular lenses (IOLs) on posterior capsule opacification (PCO) after cataract surgery.
SETTING: St. Erik's Eye Hospital, Stockholm, Sweden.
METHODS: In a prospective study, 120 patients having cataract surgery were randomized to implantation of a hydrophilic acrylic IOL (BL27, Bausch & Lomb) or a hydrophobic acrylic IOL (AcrySof SA60AT, Alcon). Surgery was performed according to a standardized protocol by 1 of 3 surgeons. Best corrected visual acuity, contrast sensitivity, glare, intraocular pressure, and flare were measured 1 week, 3 months, and 1 year after surgery. Posterior capsule opacification was assessed by digital retroillumination photography and analysis using POCOman software at 1 year. The rate of neodymium:YAG (Nd:YAG) capsulotomy for each IOL was also recorded.
RESULTS: At 1 year, the hydrophilic acrylic IOL group had a significantly greater percentage area and severity of PCO than the hydrophobic acrylic IOL group (P<.001). Two patients in the hydrophilic acrylic IOL group and 4 in the hydrophobic acrylic IOL group had an Nd:YAG capsulotomy within the first year (P>.05). Contrast sensitivity was significantly better in the hydrophilic acrylic group at 3 months (P<.05); however, at 12 months no difference between the IOLs was observed. There was no significant difference in the other measured parameters.
CONCLUSION: Patients with the hydrophilic acrylic BL27 IOL had a significantly greater percentage area and severity of PCO than those with the hydrophobic acrylic SA60AT IOL 1 year after surgery.
SETTING: St. Erik's Eye Hospital, Stockholm, Sweden.
METHODS: In a prospective study, 120 patients having cataract surgery were randomized to implantation of a hydrophilic acrylic IOL (BL27, Bausch & Lomb) or a hydrophobic acrylic IOL (AcrySof SA60AT, Alcon). Surgery was performed according to a standardized protocol by 1 of 3 surgeons. Best corrected visual acuity, contrast sensitivity, glare, intraocular pressure, and flare were measured 1 week, 3 months, and 1 year after surgery. Posterior capsule opacification was assessed by digital retroillumination photography and analysis using POCOman software at 1 year. The rate of neodymium:YAG (Nd:YAG) capsulotomy for each IOL was also recorded.
RESULTS: At 1 year, the hydrophilic acrylic IOL group had a significantly greater percentage area and severity of PCO than the hydrophobic acrylic IOL group (P<.001). Two patients in the hydrophilic acrylic IOL group and 4 in the hydrophobic acrylic IOL group had an Nd:YAG capsulotomy within the first year (P>.05). Contrast sensitivity was significantly better in the hydrophilic acrylic group at 3 months (P<.05); however, at 12 months no difference between the IOLs was observed. There was no significant difference in the other measured parameters.
CONCLUSION: Patients with the hydrophilic acrylic BL27 IOL had a significantly greater percentage area and severity of PCO than those with the hydrophobic acrylic SA60AT IOL 1 year after surgery.
Предметные рубрики MeSH
Acrylic ResinsAgedAged, 80 and overCataractContrast SensitivityFollow-Up StudiesHumansHydrophobic and Hydrophilic InteractionsIntraocular PressureLaser TherapyLens Capsule, CrystallineLens Implantation, IntraocularLenses, IntraocularMiddle AgedPhacoemulsificationPostoperative ComplicationsProspective StudiesProsthesis DesignVisual Acuity