MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · [Zhonghua yan ke za zhi] Chinese journal of ophthalmology · 2006

[Comparison of wavefront aberrations in pseudophakia with three types of intraocular lenses implantation].

Yao Ke, Zhang Zheng, Xu Wen, Chen Pei-qing, Shentu Xing-chao

Сравнительное исследованиеАннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

We compared wavefront aberration in pseudophakic eyes with 3 types of intraocular lenses (IOLs) implantation in order to obtain an objective evaluation of the optical quality of these pseudophakic eyes.

METHODS

This prospective study comprised 76 cataract patients (80 eyes) who had phacoemulsification surgery. The intraocular lenses of AcrySof MA30BM, Hydroview H60M, and Canon Staar, KS-1 were implanted in the patients at the numbers of 26, 27 and 27 eyes in each group respectively. Three months after cataract surgery, aberrations in the eyes were measured in un-dilated pupil using a Hartmann-Shack-type aberrometer (Asclepion-Meditec). The same measurements were done in 26 normal phakic eyes in age-matched persons. Individual Zernike polynomials, coma-like aberration, spherical aberration, the RMS value of total aberrations and total high order aberrations in the each group were compared.

RESULTS

The total high order aberrations (the RMS value of 3rd and 4th aberrations) in AcrySof group was higher than Canon Staar group (P = 0.011), and the Z (3, 1) Zernike coefficient in AcrySof group was significant difference compared with Hydroview group (P = 0.038).

CONCLUSION

No significant differences in higher-order aberrations among eyes are demonstrated after implantation with 3 types IOLs in un-dilated pupil. The results suggest that there is no difference in the retinal image of pseudophakic eyes with 3 types of IOLs in regular condition.

Для цитирования: Yao Ke, Zhang Zheng, Xu Wen, Chen Pei-qing, Shentu Xing-chao. [Comparison of wavefront aberrations in pseudophakia with three types of intraocular lenses implantation].. [Zhonghua yan ke za zhi] Chinese journal of ophthalmology. 2006.