MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Italian journal of gastroenterology and hepatology · 1997

Quality control study of H2 breath testing for the diagnosis of carbohydrate malabsorption in Italy. The "Tenue Club" Group.

Strocchi A, Corazza G R, Anania C, Benati G, Malservisi S, Cherchi M V, Certo M, Malorgio E, Marano M, Mazzeo V, Ginaldi L, Giorgetti G M, Pimpo T, Sciarretta G, Ventrucci M, Quondamcarlo C, Pelli M A, Perri F

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIMS: H2 breath testing is increasingly used in Italy. The aim of this multicenter study was to assess the accuracy of this technique in the diagnosis of carbohydrate malabsorption.

METHODS

An anonymous questionnaire was used to collect information about H2 breath testing methods and to design the quality control study. Fifteen out of 23 laboratories responded to the questionnaire and 12/23 completed the entire study.

RESULTS

The survey revealed that a large variety of H2 testing methods are employed in Italy, but none have been previously tested for accuracy. This prospective study showed that these tests fail to identify > 20% of patients with malabsorption. In contrast, a new method based on single H2 breath measurement at 6 hours after lactulose ingestion and a cutoff value of greater than 5 ppm, had a sensitivity of 92% +/- 4% and a specificity of 94% +/- 0.5%. Increasing the cut-off to 10 ppm resulted in a sensitivity of 88% +/- 9% and a specificity of 100%. This improved accuracy was obtained with a much simpler testing procedure in which only one breath sample is analyzed, in contrast to the baseline and multiple subsequent samples that are analyzed using the currently employed techniques.

CONCLUSIONS

A great improvement in the accuracy of the H2 breath test, as well as a considerable saving in terms of time and costs, may be possible through the use of a new, simplified H2 breath test followed by careful H2 analysis.

Для цитирования: Strocchi A, Corazza G R, Anania C, Benati G, Malservisi S, Cherchi M V, Certo M, Malorgio E, Marano M, Mazzeo V, Ginaldi L, Giorgetti G M, Pimpo T, Sciarretta G, Ventrucci M, Quondamcarlo C, Pelli M A, Perri F. Quality control study of H2 breath testing for the diagnosis of carbohydrate malabsorption in Italy. The "Tenue Club" Group.. Italian journal of gastroenterology and hepatology. 1997.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.