m+Medelevator.RU
← Поиск публикаций
The Journal of surgical research · 2025

Reliability and Construct Validity of Patient-Reported Outcome Measurement Information System Physical Function in Patients With Peripheral Artery Disease.

СтатьяВалидационное исследованиеПоддержка NIH: внешняя программаНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Holeman Teryn A, Findley Blake, Chester Cassidy, Hales Julie, Wei Yingjia, Brooke Benjamin S, Cizik Amy

Аннотация

INTRODUCTION: The construct validity of the National Institutes of Health-developed Patient-Reported Outcome Measurement Information System physical function (PROMIS-PF) instrument has not been established in patients with peripheral artery disease (PAD). This study evaluates the reliability and construct validity of PROMIS-PF compared to general and PAD-specific measures.

METHODS: Patients with PAD were recruited at a large academic medical center and completed PROMIS-PF, 36-item short-form (SF-36), Vascular Quality of Life (VascuQoL), walking impairment questionnaire (WIQ), and PROMIS-depression instruments at two time points. Intraclass correlation coefficients assessed test-retest reliability. Spearman rank correlations between PROMIS-PF and similar functional measures evaluated convergent validity, while emotional wellbeing measures served as a discriminant comparison.

RESULTS: Twenty-one patients completed questionnaires for both time points with a mean age of 71.5 ± 8.2 y. The cohort was 33% female, with 53% living in moderate or high areas of deprivation. Nineteen percent had chronic limb ischemia, and 76% underwent prior revascularization for PAD. The reliability of the PROMIS-PF was 0.96 (confidence interval [CI] 0.89-0.98) compared to 0.96 (CI 0.92-0.98), 0.95 (0.91-0.98), and 0.79 (CI 0.50-0.92) for the VascuQoL, SF-36 physical function component score, and WIQ, respectively. PROMIS-PF had the strongest correlations with the WIQ (rho = 0.86, P < 0.0001) and VascuQoL (0.85, P < 0.0001) and had the lowest correlation with the SF-36 emotional wellbeing component score (0.15, P = 0.52).

CONCLUSIONS: PROMIS-PF is a reliable and valid measure of physical function in PAD, demonstrating strong correlations with PAD-specific function measures and discriminant validity with unrelated constructs. These findings support its use in clinical research and PAD patient care.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты