m+Medelevator.RU
← Поиск публикаций
Optometry and vision science : official publication of the American Academy of Optometry · 2019

Clear and Single Binocular Vision in Near 3D Displays.

СтатьяПоддержка NIH: внешняя программаНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

McCormack Glen L, Hogan Katherine M

Аннотация

SIGNIFICANCE: Accommodation/convergence mismatch induced by 3D displays can cause discomfort symptoms such as those induced by accommodation/convergence mismatch in clinical vergence testing. We found that the limits of clear and single vision during vergence tests are very different between 3D and clinical tests. Clinical vergences should not be used as substitutes for measures of vergences in 3D displays.

PURPOSE: The purposes of this study were to determine whether the limits of clear and single binocular vision derived from phoropter prism vergence tests match the limits measured in a 3D display and to determine whether vergence mode, smooth versus jump, affected those limits in the 3D display.

METHODS: We tested the phoropter prism vergence limits of clear and single vision at 40 cm in 47 binocular young adults. In separate sessions, we tested, in a 3D display, the analogous 40-cm vergence limits for smooth vergence and jump vergence. The 3D fixation target was a Maltese cross whose visual angle changed congruently with target disparity.

RESULTS: Our mean phoropter vergence blur and break values were similar to those reported in previous studies. The mean smooth divergence limit was less in the 3D display (9.8Δ) than in the phoropter (12.8Δ). Most smooth convergence limits were much larger in the 3D display than in the phoropter, reaching the 35Δ limit of the 3D display without blur or diplopia in 24 subjects. Mean jump vergence limits were significantly smaller than smooth vergence limits in the 3D display.

CONCLUSIONS: The limits of clear and single binocular vision derived from phoropter vergence tests were not a good approximation of the analogous limits in our 3D display.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты