MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.18-25571

Медицинская библиотека · Investigative ophthalmology & visual science · 2018

Clinically Relevant Immune-Cellular Metrics of Inflammation in Meibomian Gland Dysfunction.

Qazi Yureeda, Kheirkhah Ahmad, Blackie Caroline, Trinidad Monique, Williams Candice, Cruzat Andrea, Korb Donald R, Hamrah Pedram

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the reliability and clinical relevance of in vivo confocal microscopy (IVCM)-based immune-cellular metrics of palpebral conjunctival inflammation in meibomian gland dysfunction (MGD).

METHODS

Sixteen MGD patients and 13 reference controls included in this cross-sectional, retrospective study, had an ocular surface exam, symptom assessment (Ocular Surface Disease Index questionnaire [OSDI]), and palpebral conjunctival IVCM imaging. Bland-Altman analyses, intraclass correlation coefficient (ICCa), Lin's concordance correlation coefficient (ρc), receiver operating characteristic (ROC) analyses, and correlations were performed. Clinical outcome measures were symptom severity (OSDI scores), tear break-up time (TBUT), and corneal fluorescein staining (CFS grade).

RESULTS

Compared to controls, patients with MGD had variable symptom severity (average OSDI score: 48.3 ± 7.6, P = 0.0008, range: 8.3-85.42), shorter TBUT (6.8 ± 0.9 seconds, P = 0.002), comparable corneal staining (0.31 ± 0.19, P = 0.20), and greater conjunctival inflammation (epithelial immune cells [EIC]: 477.8 ± 54.2 vs. 123.3 ± 17.2 cells/mm2, P < 0.0001; intraglandular immune cells [IGIC]: 41.9 ± 3.3% vs. 20.33 ± 7.3%, P < 0.01). Immune-cellular metrics had high inter- and intraobserver agreement (ρc: 0.86-0.94; ICCa and Cronbach's α: 0.85-0.97, P < 0.0001). EIC correlated positively with OSDI (rs: 0.49, P = 0.03), while both EIC and IGIC correlated inversely with TBUT (rs: -0.47, -0.45, P < 0.05), and had high accuracy in detecting inflammation (ROC area under the curve [AUC]: 0.97 and 0.89, P ≤ 0.001).

CONCLUSIONS

EIC and IGIC are increased in highly symptomatic patients with MGD that have minimal corneal staining, and correlate with symptoms and clinical signs. EIC and IGIC may provide reliable and clinically relevant metrics of inflammation.

Для цитирования: Qazi Yureeda, Kheirkhah Ahmad, Blackie Caroline, Trinidad Monique, Williams Candice, Cruzat Andrea, Korb Donald R, Hamrah Pedram. Clinically Relevant Immune-Cellular Metrics of Inflammation in Meibomian Gland Dysfunction.. Investigative ophthalmology & visual science. 2018. DOI: 10.1167/iovs.18-25571.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.