Value of three-dimensional endoanal ultrasound scan (3D-EAUS) in preoperative assessment of fistula-in-ano.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Almeida Isuru Sampath, Jayarajah Umesh, Wickramasinghe Dakshitha Praneeth, Samarasekera Dharmabandhu Nandadeva
Аннотация
OBJECTIVE: The aim of this study was to determine the accuracy of three-dimensional endoanal ultrasound scan (3D-EAUS) in the pre-operative assessment of fistula-in-ano in identifying the fistula tract and comparing with findings at surgery in a South Asian cohort. A retrospective analysis of 87 patients with suspected fistula-in-ano who underwent pre-operative 3D-EAUS between January 2009 and January 2016 was carried out. All patients subsequently had surgical exploration under anaesthesia (EUA), irrespective of 3D-EAUS findings. The 3D-EAUS results were compared with the surgical findings to determine the accuracy of 3D-EAUS.
RESULTS: A total of 86 (98.9%) patients (male = 75) were subsequently shown to have a fistula at surgical exploration and of them, 3D-EAUS detected a fistula in 79 (92%) patients. In this cohort, 3D-EAUS correctly predicted the surgical findings in (n = 61, 70.9%) patients with the highest accuracy being for transphincteric fistulae (87.1%). However, the overall concordance in our study was low with a kappa coefficient of 0.318. Additional findings such as sphincter defects were detected by the 3D-EAUS in 37 patients (internal sphincter defects-21, external sphincter defects-7, both-9) which were not evident at EUA. Therefore, 3D-EAUS had a good accuracy in selected types of fistulae and particularly useful in identifying sphincter defects before surgery.
RESULTS: A total of 86 (98.9%) patients (male = 75) were subsequently shown to have a fistula at surgical exploration and of them, 3D-EAUS detected a fistula in 79 (92%) patients. In this cohort, 3D-EAUS correctly predicted the surgical findings in (n = 61, 70.9%) patients with the highest accuracy being for transphincteric fistulae (87.1%). However, the overall concordance in our study was low with a kappa coefficient of 0.318. Additional findings such as sphincter defects were detected by the 3D-EAUS in 37 patients (internal sphincter defects-21, external sphincter defects-7, both-9) which were not evident at EUA. Therefore, 3D-EAUS had a good accuracy in selected types of fistulae and particularly useful in identifying sphincter defects before surgery.