Diagnostic Performance of CT-Derived Fractional Flow Reserve in Australian Patients Referred for Invasive Coronary Angiography.
Аннотация
BACKGROUND
Non-invasive computed tomography (CT)-derived fractional flow reserve (FFRCT) is computed from standard coronary CT angiography (CTA) datasets and provides accurate vessel-specific ischaemia assessment of coronary artery disease (CAD). To date, the technique and its diagnostic performance has not been verified in the Australian clinical context. The aim of this study was to describe and compare the diagnostic performance of FFRCT and CTA for the detection of vessel-specific ischaemia as determined by invasive fractional flow reserve (FFR) in the Australian patient population.
METHODS
One-hundred-and-nine patients (219 vessels) referred for clinically mandated invasive angiography were retrospectively assessed. Each patient underwent research mandated CTA and FFRCT within 3 months of invasive angiography and invasive FFR assessment. Independent core laboratory assessments were made to determine visual CTA stenosis, FFRCT and invasive FFR values. FFRCT values were matched with the corresponding invasive FFR measurement taken at the given wire position. Visual CTA stenosis ≥50%, FFRCT values ≤0.8 and invasive FFR values ≤0.8 were considered significant for ischaemia.
RESULTS
Per vessel accuracy, sensitivity, specificity, positive predictive value and negative predictive value of FFRCT were 80.4%, 80.0%, 80.6%, 64.9% and 90.0% respectively. Corresponding values for CTA were 75.1%, 87.1%, 69.2%, 58.1% and 91.7% respectively. In receiver operating characteristic curve analysis, FFRCT demonstrated superior area under the curve (AUC) compared with CTA in both per vessel (0.87 vs 0.77, p=0.004) and per patient analysis (0.86 vs 0.74, p=0.011). Per vessel AUC of combined CTA and FFRCT was superior to CTA alone (0.89 vs 0.77, p<0.0001).
CONCLUSION
In this cohort of Australian patients, the diagnostic performance of FFRCT was found to be comparable to existing international literature, with demonstrated improvement in performance compared with CTA alone for the detection of vessel-specific ischaemia.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.