MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm14082805

Медицинская библиотека · Journal of clinical medicine · 2025

Effect of Preoperative Dry Eye Treatment with Intense Pulsed Light with Meibomian Gland Expression on the Refractive Accuracy of Cataract Surgery in Patients with Meibomian Gland Dysfunction-Related Dry Eye: A Single-Center, Prospective, Open-Label Study.

Kawagoe Tatsukata, Mizuki Yuki, Akaishi Miki, Takeuchi Masaki, Yabuki Kazuro, Hata Seiichiro, Meguro Akira, Mizuki Nobuhisa, Teshigawara Takeshi

СтатьяПеревод пока не подготовлен

Аннотация

Objective

This research seeks to investigate the effects of preoperative intense pulsed light with manual meibomian expression (IPL-MGX) on the refractive accuracy of cataract surgery on dry eyes with meibomian gland dysfunction (MGD-related dry eyes).

Methods

Fifty-six MGD-related dry eye cases planned for cataract surgery were analyzed. IPL-MGX (four times at 2-week intervals) was performed before preoperative examination. Axial length (AL), anterior chamber depth (ACD), corneal curvature (mean-K), tear break-up time (TBUT), superficial punctate keratopathy in the central cornea (C-SPK), corneal higher-order aberrations (HOAs), and predicted postoperative spherical equivalent (P-SE) were evaluated pre- and post-IPL-MGX. The postoperative subjective spherical equivalent (S-SE) was evaluated after one month. The absolute difference between the S-SE and P-SE was considered an indication of P-SE accuracy. Changes in all the variables were assessed before and after IPL-MGX treatment.

Results

No significant differences were observed in AL or ACD (p = 0.85, 0.56). The differences in mean-K, TBUT, C-SPK, and HOAs were significant (p < 0.01). P-SE accuracy based on post-IPL-MGX data was significantly higher than that based on pre-IPL-MGX data (p < 0.01). P-SE accuracy was within 0.25 diopters (D) in 14.3% of pre- and 55.4% of post-IPL-MGX, within 0.5D in 55.4% of pre- and 92.9% of post-IPL-MGX, within 0.75D in 98.2% of pre- and post-IPL-MGX, and within 1.0D in 98.2% of pre- and 100% of post-IPL-MGX. In the range of 0.25 and 0.5 D, the accuracy of P-SE was significantly higher in post-IPL-MGX (p < 0.01).

Conclusions

Preoperative IPL-MGX considerably improved the predicted postoperative refraction accuracy in patients with MGD-related dry eye undergoing cataract surgery.

Для цитирования: Kawagoe Tatsukata, Mizuki Yuki, Akaishi Miki, Takeuchi Masaki, Yabuki Kazuro, Hata Seiichiro, Meguro Akira, Mizuki Nobuhisa, Teshigawara Takeshi. Effect of Preoperative Dry Eye Treatment with Intense Pulsed Light with Meibomian Gland Expression on the Refractive Accuracy of Cataract Surgery in Patients with Meibomian Gland Dysfunction-Related Dry Eye: A Single-Center, Prospective, Open-Label Study.. Journal of clinical medicine. 2025. DOI: 10.3390/jcm14082805.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.