MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20250213-01

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2025

Influence of Corneal Higher Order Aberrations on Visual Performance With a Multifocal Intraocular Lens.

Fernández Joaquín, Burguera Noemí, Calvo-de-Mora Marina Rodríguez, Rocha-de-Lossada Carlos, Rodríguez-Vallejo Manuel

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the impact of corneal aberrations on the visual performance of patients who received a multifocal intraocular lens (MIOL) implant.

METHODS

Two hundred seventy patients who underwent cataract or refractive lens exchange and were implanted with an apodized diffractive MIOL were included in the analysis. Relationships between total higher order aberrations (HOAs), coma, trefoil, and spherical aberration (SA) measured with a Scheimpflug topographer at 4 mm versus visual acuity and contrast sensitivity areas under the defocus curves (AUC) were evaluated. Relationships between other demographic and biometric variables with total AUCs were also explored.

RESULTS

Eyes rarely showed coma and trefoil aberrations exceeding 0.2 μm, 0.1 μm for SA, and 0.3 μm for the total HOAs. The total HOAs showed correlations with age (rho = 0.32, P < .0005) and anterior chamber depth (rho = -0.21, P = .001). The mesopic pupil size, age, and chart luminance, in the following order, were mainly correlated with total AUCs. A correction by mesopic pupil was required to unmask weak correlations of AUCs with the corneal aberrations. These were found particularly for total HOAs and total and near AUCs (P < .05).

CONCLUSIONS

Values below 0.3 μm for total HOAs, 0.2 μm for coma and trefoil, and 0.1 μm for SA at 4 mm are safe for the study IOL. Higher values are rare but still can be safe, and the 0.5 μm cut-off at 4 mm for contraindication merits further research with this and other IOLs. [J Refract Surg. 2025;41(4):e291-e299.].

Для цитирования: Fernández Joaquín, Burguera Noemí, Calvo-de-Mora Marina Rodríguez, Rocha-de-Lossada Carlos, Rodríguez-Vallejo Manuel. Influence of Corneal Higher Order Aberrations on Visual Performance With a Multifocal Intraocular Lens.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2025. DOI: 10.3928/1081597x-20250213-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.