MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tbme.2021.3119188

Медицинская библиотека · IEEE transactions on bio-medical engineering · 2022

A Personalized Pulmonary Circulation Model to Non-Invasively Calculate Fractional Flow Reserve for Artery Stenosis Detection.

Chen Zhenyang, Zhou Yu-Ping, Liu Xiujian, Jiang Xin, Wu Tao, Ghista Dhanjoo, Xu Xi-Qi, Zhang Heye, Jing Zhi-Cheng

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

Fractional Flow Reserve (FFR) is regarded as a fundamental index to assess pulmonary artery stenosis. The application of FFR can increase the accuracy of detection of pulmonary artery stenosis. However, the invasive examination may carry a number of physiological risks for patients. Therefore, we propose a personalized pulmonary circulation model to non-invasively calculate FFR of pulmonary artery stenosis.

METHODOLOGY: We have employed a personalized pulmonary circulation model to non-invasively calculate FFR. This model combines boundary condition estimation and 3D pulmonary artery morphology reconstruction for CFD simulation. Firstly, we obtain patient-specific boundary conditions by matching cardiac output and main pulmonary artery pressure. Secondly, the 3D pulmonary artery morphology is reconstructed by semi-automatic segmentation. The CFD simulation is performed to obtain the pressure distribution in the entire pulmonary artery. Finally, the FFR in pulmonary artery stenosis is calculated as the ratio of distal pressure and proximal pressure.

RESULTS

To validate our model, we compare the simulated FFR with the measured FFR by pressure guide wires examination of 20 patients. The FFR simulated by our model shows a good agreement with the measured FFR by pressure guide wires examination ( r= 0.989, 0.001).

CONCLUSION

Our proposed personalized pulmonary circulation model is shown to be capable of non-invasively calculating FFR with sufficient accuracy.

SIGNIFICANCE: The FFR calculated by our personalized circulation model may effectively contribute to non-invasive detection of pulmonary artery stenosis and to a comprehensive evaluation of the entire pulmonary artery vascular tree.

Для цитирования: Chen Zhenyang, Zhou Yu-Ping, Liu Xiujian, Jiang Xin, Wu Tao, Ghista Dhanjoo, Xu Xi-Qi, Zhang Heye, Jing Zhi-Cheng. A Personalized Pulmonary Circulation Model to Non-Invasively Calculate Fractional Flow Reserve for Artery Stenosis Detection.. IEEE transactions on bio-medical engineering. 2022. DOI: 10.1109/tbme.2021.3119188.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.