MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000515658

Медицинская библиотека · Gerontology · 2021

Orthostatic Blood Pressure Recovery Measured Using a Sphygmomanometer Is Not Associated with Physical Performance or Number of Falls in Geriatric Outpatients.

Mol Arjen, Blom Marieke Esmé Charlotte, van den Bosch Danique Johanna, Van Wezel Richard Jack Anton, Meskers Carel G M, Maier Andrea B

НовостьПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Orthostatic hypotension (OH) and impaired OH recovery derived from beat-to-beat blood pressure (BP) measurements are associated with detrimental clinical outcome, but the clinical relevance of OH recovery assessed using the widely available sphygmomanometer is still unclear.

METHOD: 635 geriatric outpatients underwent comprehensive geriatric assessment, including orthostatic BP measurements using a sphygmomanometer, during supine rest and 1 and 3 min after standing up and assessment of physical performance (i.e., the timed up and go test and the Short Physical Performance Battery) and the number of falls in the past year. The association between BP recovery, defined as BP at 3 min minus BP at 1 min after standing up, with physical performance and falls was assessed using regression analyses, adjusting for age and sex, both in the entire cohort and after stratifying for the presence of OH at 1 min after standing up.

RESULTS

BP recovery was not associated with physical performance or number of falls, neither in the entire cohort, nor in subpopulations with or without OH.

CONCLUSION

The clinical relevance of BP recovery between 1 and 3 min after standing up could not be demonstrated. The results suggest that sphygmomanometer measurements have an inadequate time resolution to record the clinically relevant dynamics of orthostatic BP recovery.

Для цитирования: Mol Arjen, Blom Marieke Esmé Charlotte, van den Bosch Danique Johanna, Van Wezel Richard Jack Anton, Meskers Carel G M, Maier Andrea B. Orthostatic Blood Pressure Recovery Measured Using a Sphygmomanometer Is Not Associated with Physical Performance or Number of Falls in Geriatric Outpatients.. Gerontology. 2021. DOI: 10.1159/000515658.