m+Medelevator.RU
← Поиск публикаций
BJOG : an international journal of obstetrics and gynaecology · 2024

Accuracy of sonographic lower segment thickness and prediction of vaginal birth after caesarean in a resourced-limited setting; Prospective study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Adu-Takyi Charles, Munazzah Rafique, Owusu Yaw Gyanteh, Owusu-Bempah Atta, Arhin Bernard, Opare-Addo Henry Sakyi, Peprah Amponsah, Collins Sally L, Adu-Bredu Theophilus

Аннотация

OBJECTIVES: To assess the accuracy of ultrasound measurement of the lower uterine segment (LUS) thickness against findings at laparotomy, and to investigate its correlation with the success rate of vaginal birth after one previous caesarean delivery (CD) in a resource-limited setting.

DESIGN: Prospective study.

SETTING: Obstetrics and Gynaecology department in a tertiary hospital in Ghana.

POPULATION: Women with one previous CD undergoing either a trial of labour (TOLAC) or elective CD.

METHODS: Myometrial lower uterine segment thickness (mLUS) and full lower uterine segment thickness (fLUS) were measured with transvaginal ultrasound (TVUS). The women were managed according to local protocols with the clinicians blinded to the ultrasound measurements. The LUS was measured intraoperatively for comparison with ultrasound measurements.

MAIN OUTCOME MEASURES: Lower uterine segment findings at laparotomy, successful vaginal birth.

RESULTS: A total of 311 pregnant women with one previous CD were enrolled; 147 women underwent elective CD and 164 women underwent a TOLAC. Of the women that underwent TOLAC, 96 (58.5%) women had a successful vaginal birth. The mLUS was comparable to the intraoperative measurement in the elective CD group with LUS thickness <5 mm (bias of 0.01, 95% CI -0.10 to 0.12 mm) whereas fLUS overestimated LUS <5 mm (bias of 0.93, 95% CI 0.80-1.06 mm). Successful vaginal birth rate correlated with increasing mLUS values (odds ratio 1.30, 95% CI 1.03-1.64). Twelve cases of uterine defect were recorded. LUS measurement ≤2.0 mm was associated with an increased risk of uterine defects with a sensitivity of 91.7% (95% CI 61.5-99.8%) and specificity of 81.8% (95% CI 75.8-86.8%).

CONCLUSION: Accurate TVUS measurement of the LUS is technically feasible in a resource-limited setting. This approach could help in making safer decisions on mode of birth in limited-resource settings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты